Kostal PIKO 10 BA Short Manual Download Page 7

12

13

12

13

Connecting AC and DC side

  LEBENSGEFAHR DURCH STROMSCHLAG! 

  Wechselrichter spannungsfrei schalten.
  RISK OF DEATH DUE TO ELECTRICAL SHOCK! 

  De-energise the inverter.
  DANGER DE MORT PAR ÉLECTROCUTION ! 

  Mettre l’onduleur hors tension.
  ¡PELIGRO DE MUERTE DEBIDO A ELECTROCUCIÓN! 

  Desconectar el inversor de la tensión.
  PERIGO DE MORTE DEVIDO A CHOQUE ELÉTRICO! 

  Desligar a tensão de corrente do inversor.
  PERICOLO DI MORTE PER SCOSSA ELETTRICA! 

  Eliminare la tensione dall‘inverter.
  LIVSFARE PGA. ELEKTRISK STØD! 

  Vekselstrømsomformeren skal kobles fra spændingen.
  LEVENSGEVAAR DOOR ELEKTRISCHE SCHOK! 

  Schakel de omvormer spanningsvrij.
  OHROŽENÍ ŽIVOTA ELEKTRICKÝM PROUDEM! 

  Odpojte střídač od napětí.
  PERICOL DE ELECTROCUTARE! 

  Scoateţi ondulorul de sub tensiune.
  SMRTNA NEVARNOST ZARADI ELEKTRIČNEGA UDARA! 

  Razsmernik odklopite iz električne napetosti.
   NEBEZPEČENSTVO OHROZENIA ŽIVOTA ZÁSAHOM 

 

ELEKTRICKÉHO PRÚDU! 

Menič prepnite do beznapäťovej prevádzky.

  ELEKTRIK ÇARPMASI NEDENIYLE HAYATI TEHLIKE! 

  İnvertörü gerilimsiz hale getirin.
  ΚΊΝΔΥΝΟΣ ΘΑΝΑΤΟΥ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΊΑ! 

  Αποσυνδέστε τον αντιστροφέα από το ρεύμα.

   ОПАСНОСТ ЗА ЖИВОТА ПОРАДИ ТОКОВ УДАР. 

Изключвайте инвертора от напрежението.

  LIVSFARA PÅ GRUND AV ELEKTRISK STÖT! 

  Koppla växelriktaren spänningsfri.
  ZAGROŻENIE ŻYCIA PRZEZ PORAŻENIE PRĄDEM! 

  Odłączyć falownik od zasilania.
  ELEKTRILÖÖGI OHT! 

  Lahutage vaheldi vooluvõrgust.
  PAVOJUS GYVYBEI DĖL ELEKTROS SROVĖS SMŪGIO! 

  Inverteriui nutraukite įtampos tiekimą.
  ELEKTRISKĀS STRĀVAS TRIECIENA BRIESMAS! 

  Atslēgt invertoru no strāvas.
  OPASNOST PO ŽIVOT OD STRUJNOG UDARA! 

  Isključiti izmjenjivač.
  OPASNOST PO ŽIVOT ZBOG STRUJNOG UDARA! 

  Isključiti izmjenjivač.
  OPASNOST PO ŽIVOT USLIJED STRUJNOG UDARA! 

  Izmjenjivač isključite sa naponskog napajanja.
  OPASNOST PO ŽIVOT USLED STRUJNOG UDARA! 

  Izmenjivač isključite sa naponskog napajanja.

De-energising inverter:

OFF

ON

OFF

5 min

Switch off DC side

1. At Inverter
2. At Batterysystem 
(when connected)

Switch off  

- AC side 

- S0/AL-out 

- Battery 

(when connected)

Safeguard

Disconnect  

DC side

Wait 5 minutes

1.

2.

3.

4.

5.

Summary of Contents for PIKO 10 BA

Page 1: ...Short Manual PIKO 6 0 BA 8 0 BA 10 BA with Energy Management...

Page 2: ...ers Part 2 EU Declaration of conformity Directive 2004 108 EC Electromagnetic compatibility Directive 2006 95 EC Electrical Apparatus Low Voltage Directive Application of the CE marking in accordance...

Page 3: ...te operation manual on the CD Exclusion of liability Any use that differs from or goes beyond the stated intended purpose is con sidered inappropriate The manufacturer accepts no liability for any dam...

Page 4: ...type 3 Item number 4 MPP control range 5 Maximum DC input voltage 6 Maximum DC input current 7 Maximum DC short circuit current 8 Number of feed in phases Output voltage nominal frequency Maximum AC...

Page 5: ...C Air humidity must be between 4 and 100 condensing Selecting the installation side NOTE Observe the following instructions or else warranty claims will be restricted Select stable installation locat...

Page 6: ...10 11 10 11 Installation 200 200 100 100 45 20 74 45 max 10 To lift the inverter 2 3 1 Cooling space Mounting spaces PIKO BA Inverter Lift here Lift here...

Page 7: ...ne napetosti NEBEZPE ENSTVO OHROZENIA IVOTA Z SAHOM ELEKTRICK HO PR DU Meni prepnite do beznap ovej prev dzky ELEKTRIK ARPMASI NEDENIYLE HAYATI TEHLIKE nvert r gerilimsiz hale getirin LIVSFARA P GRUND...

Page 8: ...g Backup Unit Connecting AC Connecting AC Connecting sensor Connecting battery Connecting DC side Connecting Backup Unit optional equipment 1 2 L1 k L1 l L2 k L2 l L3 k L3 l Sensor Battery DSL LAN CAN...

Page 9: ...n this feature must be acti vated under the menue Settings Hardware settings String connection Parallel connection Connecting main cable with sealing cap Second ground connection Country specific inst...

Page 10: ...18 19 18 19 Data transfer Communicationboard II DSL or LAN and CAN bus DSL LAN CAN bus Commissioning the inverter OFF ON 1 2 3 ON 5 Nm...

Page 11: ...ion Wizard Country setting Do you really want to apply this country No Yes Language German 1 Select language 2 H Enter 3 Enter Date time 4 H Enter 5 Select string connection 6 H Enter 7 Select modus o...

Page 12: ...C menu DC input 1 U I P DC input 2 U I P Phase 1 U I P Phase 2 U I P Phase 3 U I P Total yield Yield MWh Operation time h Grid parameters Limitation on Grid frequency Hz cos Daily yield diagram Monthl...

Page 13: ...connection Paralell connection Currentsensor Position Modus Battery settings Battery charge time Start time End time Communication Network settings 1 Auto IP Network settings 2 IP address Subnet mask...

Page 14: ...Menu Consumption Daily own consumption Own consumption Wh Own consumptions rate Autonomy degree Total own consumption Own consumption Wh Own consumptions rate Autonomy degree Current build consump Bat...

Page 15: ...voltage V 153 Max charge current A 12 Max discharge current A 12 Inverter PIKO Unit 6 0 BA 8 0 BA 10 BA Output side AC Rated output cos j 1 Pac r kW 6 8 10 Max output apparent power cos adj kVA 6 8 10...

Page 16: ...Inverter PIKO Unit 6 0 BA 8 0 BA 10 BA System data Topology without galvanic separation transformerless H Internal protection according to IEC 60529 IP 55 Protection class according to IEC 62103 I Ov...

Page 17: ...Germany and other countries1 49 761 47 74 42 22 Service Hotline 1 Language German English 12 2015 edition subject to technical changes and printing errors...

Reviews: