Kostal PIKO 10 BA Short Manual Download Page 13

24

25

24

25

Settings menu

1

1

Deviations due to software versions (UI level) is possible. 

2

After entering the code, additional menu items appear to configure the inverter.  

 The code can be obtained by electricians from our customer service.

  Basic settings  

  Language  

  Select language

  Inverter name  

  Entering the name

  Date / time   

  Set date / Set time of day

  Hardware settings  

  String connection  

  Paralell connection

  Currentsensor Position

 Modus

  Battery settings  

  Battery charge time  

  Start time / End time

  Communication  

  Network settings 1  

  Auto IP

  Network settings 2  

  IP address / Subnet mask

  Router settings  

  External router / Router IP

  RS485 settings  

  Bus termination / Bus bias voltage / RS485 address

  Portal configuration  

  Portal code / Data export

  Event messages  

  Immediately  mailing  On / Off

  Device information  

  SW/HW version  

  FW / HW / UI / PAR

  Serial number  

  Serial number

  Country setting  

  Country setting

  Function test  

  Fan test  

  Service menu  

  Service code

2

  Factory settings

Summary of Contents for PIKO 10 BA

Page 1: ...Short Manual PIKO 6 0 BA 8 0 BA 10 BA with Energy Management...

Page 2: ...ers Part 2 EU Declaration of conformity Directive 2004 108 EC Electromagnetic compatibility Directive 2006 95 EC Electrical Apparatus Low Voltage Directive Application of the CE marking in accordance...

Page 3: ...te operation manual on the CD Exclusion of liability Any use that differs from or goes beyond the stated intended purpose is con sidered inappropriate The manufacturer accepts no liability for any dam...

Page 4: ...type 3 Item number 4 MPP control range 5 Maximum DC input voltage 6 Maximum DC input current 7 Maximum DC short circuit current 8 Number of feed in phases Output voltage nominal frequency Maximum AC...

Page 5: ...C Air humidity must be between 4 and 100 condensing Selecting the installation side NOTE Observe the following instructions or else warranty claims will be restricted Select stable installation locat...

Page 6: ...10 11 10 11 Installation 200 200 100 100 45 20 74 45 max 10 To lift the inverter 2 3 1 Cooling space Mounting spaces PIKO BA Inverter Lift here Lift here...

Page 7: ...ne napetosti NEBEZPE ENSTVO OHROZENIA IVOTA Z SAHOM ELEKTRICK HO PR DU Meni prepnite do beznap ovej prev dzky ELEKTRIK ARPMASI NEDENIYLE HAYATI TEHLIKE nvert r gerilimsiz hale getirin LIVSFARA P GRUND...

Page 8: ...g Backup Unit Connecting AC Connecting AC Connecting sensor Connecting battery Connecting DC side Connecting Backup Unit optional equipment 1 2 L1 k L1 l L2 k L2 l L3 k L3 l Sensor Battery DSL LAN CAN...

Page 9: ...n this feature must be acti vated under the menue Settings Hardware settings String connection Parallel connection Connecting main cable with sealing cap Second ground connection Country specific inst...

Page 10: ...18 19 18 19 Data transfer Communicationboard II DSL or LAN and CAN bus DSL LAN CAN bus Commissioning the inverter OFF ON 1 2 3 ON 5 Nm...

Page 11: ...ion Wizard Country setting Do you really want to apply this country No Yes Language German 1 Select language 2 H Enter 3 Enter Date time 4 H Enter 5 Select string connection 6 H Enter 7 Select modus o...

Page 12: ...C menu DC input 1 U I P DC input 2 U I P Phase 1 U I P Phase 2 U I P Phase 3 U I P Total yield Yield MWh Operation time h Grid parameters Limitation on Grid frequency Hz cos Daily yield diagram Monthl...

Page 13: ...connection Paralell connection Currentsensor Position Modus Battery settings Battery charge time Start time End time Communication Network settings 1 Auto IP Network settings 2 IP address Subnet mask...

Page 14: ...Menu Consumption Daily own consumption Own consumption Wh Own consumptions rate Autonomy degree Total own consumption Own consumption Wh Own consumptions rate Autonomy degree Current build consump Bat...

Page 15: ...voltage V 153 Max charge current A 12 Max discharge current A 12 Inverter PIKO Unit 6 0 BA 8 0 BA 10 BA Output side AC Rated output cos j 1 Pac r kW 6 8 10 Max output apparent power cos adj kVA 6 8 10...

Page 16: ...Inverter PIKO Unit 6 0 BA 8 0 BA 10 BA System data Topology without galvanic separation transformerless H Internal protection according to IEC 60529 IP 55 Protection class according to IEC 62103 I Ov...

Page 17: ...Germany and other countries1 49 761 47 74 42 22 Service Hotline 1 Language German English 12 2015 edition subject to technical changes and printing errors...

Reviews: