Kospel PPE2 Service Manual Download Page 15

15

Pos.

Service code

Picture number

Name

Notice

1

01274

KDE2-03.00.00/1

Heating box KDE2 15kW/400V

1

Power 9/12/15 kW

01277

KDE2-03.00.00/2

Heating box KDE2 24kW/400V

Power 18/21/24 kW

01278

KDE2-03.00.00/3

Heating box KDE2 27kW/400V

2
3

01348

PPH2-01.00.00

Bottom wall PPE2/PPH2

1

4

01349

PPH2-09.00.00

Front cover PPE2/PPH2

1

5

01347

PPE2-05.00.00

Control panel PPE2

1

6

1

7

01344

PPE2-02.00.00

Inlet connection pipe PPE2

1

8

01346

PPE2-04.00.00

Intermediate connection PPE2

1

9

01350

PPE2-03.01.00

Power board pipe PPE2

1

10

01285

KDH2-04.00.00

Outlet connection pipe KDE2/PPE2

1

11

1

12

01345

PPE2-03.00.00

Power board PPE2

1

13

01396

KDE2-11.00.00

MSP-81 board for PPE2/PPVE

1

01280

KDE2-11.00.00/01/0-1

MSP-80 board for PPE2/PPVE

1

15

1

16

1

17

01282

TT4-G10KC3-34-330-

KOS

Temperature sensor in/out

2

18

01284

WM-151

Air sensor

1

19

00007

CZP-00.00.00A/XX

Flow sensor

1

20

01281

WC3a-00.00.00/02

Safety cut-out WC-3

1

21

WM-148

Support

1

22

01298

WP-055

Body of heating box

1

23

01299

WP-060

Top cover of heating box

1

24

01301

WP-101

Top gasket of heating box

1

25

01300

WP-061

Bottom cover of heating box

1

26

01302

WP-100

Bottom gasket of heating box

1

27

01303

KDE2-03.01.00/1

Heating element 2,5kW (KDE2 15kW/400V)

6

01304

KDE2-03.01.00/2

Heating element 4kW (KDE2 24kW/400V)

6

01305

KDE2-03.01.00/3

Heating element 4,5kW (KDE2 27kW/400V)

6

28

WM-157

Bridge

5

29

01306

CV15FR 31.2014.10003  Check valve KDE2 15kW/400V

1

7L Zielony

01307

CV15FR 31.2020.00001

Check valve KDE2 24kW/400V

1

10L Niebieski

00617

CV15 DN10 31.4015.0

Check valve KDE2 27kW/400V

1

CV15DN10

30

WE-010

Screw connection

1

31

00245

WP-040

Mesh filter 1/2"

1

32

01283

WM-156

Staple

4

33
34
35

00253

WP-054.02

Gasket 1.5x14,8x8 (3/8")

1

36

00255

WP-054.07

Gasket 1.5x18,2x11,7 (1/2")

4

37

00337

PN-60/M-86961

O-ring 3,3x2,4

4

38

00627

Oring 5,1x1,6

39
40

WM-001

Ground terminal

1

41

Terminal stripe TLZ16 (4/12)

1

42

00145

Ball-tap mini 1/2"

1

43

MARCOPOL

Screw TW 3,1x8 TX

1

44

MARCOPOL

Screw TW 3,1x25 PZ

2

45

MARCOPOL

Screw UW 4,5x30 TBH/1

12

46

PN-86/M-82144

Nut M5-5-A-Fe/Zn5

24

9.   Spare parts list.

Tab.4.  Parts list.

Summary of Contents for PPE2

Page 1: ...1 KOSPEL S A KOSZALIN ul Ol cho wa 1 SERVICE MANUAL PPE2 11 06 2015...

Page 2: ...e of power configuration for heating boxes 15 24 27 kW 8 4 1 Description of MSP 81 board 9 Pic 4 1 MSP 81 board 9 Tab 2 1 Configuration of dipswitches P and F 9 5 Electric connection of heating box 10...

Page 3: ...3 1 Exterior view of water heater PPE2 Pic 1 Water heater PPE2 4 01349 5 01347 3 01348 14 01168 Part number in table of parts Service code...

Page 4: ...Service manual PPE2 4 2 Construction of water heater PPE2 Pic 2 Interior view 8 01346 1 Tab 1 le p 5 19 00007 30 5 01347 41 10 01285 42 00145 7 01344 9 01350 12 01345 13 01280 20 01281 40...

Page 5: ...5 Pic 2a Flow sensor and air sensor 2 1 Assembly of flow sensor and air sensor 37 00337 18 01284 32 01283 29 T 15 able p 36 00255 Check valve Air sensor Correct assembly of the flow sensor WC 3 probe...

Page 6: ...Service manual PPE2 6 2 2 Assembly of temperature sensors Pic 2b Temperature sensors 37 00337 35 00253 32 01283 31 00245 36 00255 32 01283 17 01282 Outlet temp sensor Inlet temp sensor...

Page 7: ...7 Power of heating box W 2500 4000 4500 Rated voltage V 400 400 400 Rated current A 6 3 10 0 11 3 Heating element resistance 64 00 40 00 35 56 Tab 1 Parameters of heating box 38 00627 38 00627 27 Tab...

Page 8: ...LED display shows the desired temperature value which has been adjusted before the unit start up the heating icon and other possible working characteristics 1 NAST2 Control panel PPE2 connection poin...

Page 9: ...signal OUT 11 ZM Power board connection point 12 JP2 JP2 air detection jumper 13 Air sensor ground and power supply connection point Tab 2 1 Configuration of switches P and F Heating box 15kW Heating...

Page 10: ...Service manual PPE2 10 5 Electric connection of heating box Pic 5 Electric connection of heating box 1 Tab 15 le p 12 01345 20 01281 Top view Bottom view 13 01280 01396 400V AC...

Page 11: ...11 6 Dismantling of power board Pic 6 Dismantling of power board...

Page 12: ...ipe E1 heating box F1 safety cut out XG terminal stripe of heating box BV flow sensor A1 power board A2 MSP board A3 control panel PPE2 Twej inlet temp sensor Twyj outlet temp sensor NA block applianc...

Page 13: ...R T INLET inlet sensor failure ER T OUTLET outlet sensor failure ER T MAX temperature has exceeded the maximum value ER AIR 1 air bubbles in the heating box equipment detection ER AIR 2 air bubbles in...

Page 14: ...rameters setting mode will automatically exit after 5 minutes since the last adjustment 8 3 Maximum temperature Set the maximum temperature value then push and keep knob for about 5 seconds until the...

Page 15: ...1 22 01298 WP 055 Body of heating box 1 23 01299 WP 060 Top cover of heating box 1 24 01301 WP 101 Top gasket of heating box 1 25 01300 WP 061 Bottom cover of heating box 1 26 01302 WP 100 Bottom gask...

Page 16: ...6 5 7 6 8 7 9 8 Fuse rated current A 16 20 25 32 40 50 Min connecting wires connection mm2 4 x 4 4 x 4 4 x 6 4 x 6 mm2 4 x 16 The maximum allowed network impedance 0 43 0 37 0 30 Pressure in the wate...