Kospel PPE2 Service Manual Download Page 13

13

8.   Control panel PPE2.

Pic.8.  Control panel PPE2.

The heater switches on automatically straight after reaching the flow rate over 2,5 l/min. The temperature 

control system adjusts the power rate according to the water flow rate, required temperature and the temperature 

of water in the mains. The LCD backlight and   icon signalises the heating operation. If the unit reach the maxi-

mum power value which is too low for a given operating conditions the LCD display

will show “INSUF POWER’’. The LED display backlight also turns on while pushing or turning the setting 

knob. The backlight will automatically turn off when the heating operation is turned off, or if more than 50 se-

conds have passed since the last adjustment.

If you block the unit by master appliance (NA entry) the display will show
“NA BLOCK”
If the fault occurs the display will show   icon and error message.

• ER>T INLET – inlet sensor failure,
• ER> T OUTLET – outlet sensor failure,
• ER> T MAX – temperature has exceeded the maximum value,
• ER> AIR 1 – air bubbles in the heating box – equipment detection,
• ER> AIR 2 – air bubbles in the heating box – program detection.

If the display shows ER> T MAX, ER> AIR 1 or ER> AIR 2 the unit will stop heating.

The unit will not heat again until the failure is resolved and the appropriate value of water flow is reached.

8.1. Temperature adjustment.

Turn the knob to the right to increase the temperature value, or to the left to decrease it.

Push the knob to read the temperature value that is stored in memory. Push it again to read the next stored value. 

You can switch between the following settings “SINK”, “SHOWER” and “BATH”.

To change the temperature setting in memory:
• select the temperature setting by pushing the control knob,
• push the knob and keep for about 3 seconds until the value starts to flashing,
• turn the knob to adjust the value,
• push the knob to save the value.

Notice: save the new value within 10 seconds, otherwise you will lose it.

Display

Control knob

Summary of Contents for PPE2

Page 1: ...1 KOSPEL S A KOSZALIN ul Ol cho wa 1 SERVICE MANUAL PPE2 11 06 2015...

Page 2: ...e of power configuration for heating boxes 15 24 27 kW 8 4 1 Description of MSP 81 board 9 Pic 4 1 MSP 81 board 9 Tab 2 1 Configuration of dipswitches P and F 9 5 Electric connection of heating box 10...

Page 3: ...3 1 Exterior view of water heater PPE2 Pic 1 Water heater PPE2 4 01349 5 01347 3 01348 14 01168 Part number in table of parts Service code...

Page 4: ...Service manual PPE2 4 2 Construction of water heater PPE2 Pic 2 Interior view 8 01346 1 Tab 1 le p 5 19 00007 30 5 01347 41 10 01285 42 00145 7 01344 9 01350 12 01345 13 01280 20 01281 40...

Page 5: ...5 Pic 2a Flow sensor and air sensor 2 1 Assembly of flow sensor and air sensor 37 00337 18 01284 32 01283 29 T 15 able p 36 00255 Check valve Air sensor Correct assembly of the flow sensor WC 3 probe...

Page 6: ...Service manual PPE2 6 2 2 Assembly of temperature sensors Pic 2b Temperature sensors 37 00337 35 00253 32 01283 31 00245 36 00255 32 01283 17 01282 Outlet temp sensor Inlet temp sensor...

Page 7: ...7 Power of heating box W 2500 4000 4500 Rated voltage V 400 400 400 Rated current A 6 3 10 0 11 3 Heating element resistance 64 00 40 00 35 56 Tab 1 Parameters of heating box 38 00627 38 00627 27 Tab...

Page 8: ...LED display shows the desired temperature value which has been adjusted before the unit start up the heating icon and other possible working characteristics 1 NAST2 Control panel PPE2 connection poin...

Page 9: ...signal OUT 11 ZM Power board connection point 12 JP2 JP2 air detection jumper 13 Air sensor ground and power supply connection point Tab 2 1 Configuration of switches P and F Heating box 15kW Heating...

Page 10: ...Service manual PPE2 10 5 Electric connection of heating box Pic 5 Electric connection of heating box 1 Tab 15 le p 12 01345 20 01281 Top view Bottom view 13 01280 01396 400V AC...

Page 11: ...11 6 Dismantling of power board Pic 6 Dismantling of power board...

Page 12: ...ipe E1 heating box F1 safety cut out XG terminal stripe of heating box BV flow sensor A1 power board A2 MSP board A3 control panel PPE2 Twej inlet temp sensor Twyj outlet temp sensor NA block applianc...

Page 13: ...R T INLET inlet sensor failure ER T OUTLET outlet sensor failure ER T MAX temperature has exceeded the maximum value ER AIR 1 air bubbles in the heating box equipment detection ER AIR 2 air bubbles in...

Page 14: ...rameters setting mode will automatically exit after 5 minutes since the last adjustment 8 3 Maximum temperature Set the maximum temperature value then push and keep knob for about 5 seconds until the...

Page 15: ...1 22 01298 WP 055 Body of heating box 1 23 01299 WP 060 Top cover of heating box 1 24 01301 WP 101 Top gasket of heating box 1 25 01300 WP 061 Bottom cover of heating box 1 26 01302 WP 100 Bottom gask...

Page 16: ...6 5 7 6 8 7 9 8 Fuse rated current A 16 20 25 32 40 50 Min connecting wires connection mm2 4 x 4 4 x 4 4 x 6 4 x 6 mm2 4 x 16 The maximum allowed network impedance 0 43 0 37 0 30 Pressure in the wate...