22
Failures
Technical data
Electric water heater
OSV-20 OSV-30 OSV-40 OSV-50 OSV-60 OSV-80
Capacity
l
20
30
40
50
60
80
Rated pressure
MPa
0,6
Temperature range
°C
7 - 77
Rated power
W
2000
Rated voltage
220 - 240V~
Heating time 20°-60°C
h
0,45
0,67
0,89
1,14
1,43
1,86
Dimensions
A
mm
427
519
689
809
927
1167
B
246
321
491
611
731
971
C
200
400
Magnesium anode
mm
148
208
400
Weight (without water)
kg
13
15
20
22
25
30
№.
Fault
Cause
Repair
1.
Water heater does not heat
the water.
Indicator light is off .
Faulty power mains.
Faulty thermostat.
A thermal cut-out problem.
Check the fuse
Replace the thermostat (service).
Turn on or exchange the ther-
mal cut-out (servis).
2.
Water heater does not heat
the water.
Indicator light is on.
Faulty heating element.
Replace the faulty element
(service).
3. Water heater heats the water.
The indicator light is off.
Faulty indicator light .
Replace the light (service).