10
The operation of the water heater is safe and faultless if you follow the safety instruc-
tions below:
•
Check the function of the safety valve every two weeks (see „Start-up”- section).
•
A small leak from the safety valve through the outlet pipe may occur, it is a normal
operating state of the appliance. The outlet of the pipe has to remain opened.
Do not clog it, as a clogged outlet may cause a breakdown of the water heater.
•
Periodically remove the deposits from the tank. The frequency depends on the
water hardness in the region.
•
Check the magnesium anode once a year. To do it properly, take off a plug from
the top cover of the heater and a (polystyrene) cork that is situated under the
plug. Shut off the cold water valve and open the hot water tap then unscrew
anode with a 27mm spanner.
•
Every 18 months replace the magnesium anode. Provide anode’s type, capacity,
and year of assembly when ordering.
•
In order to follow hygiene guidelines the water should be periodically heated up
to the maximum temperature.
•
Every operational anomaly has to be consulted with a professional service.
•
If in the room where the water heater is installed, the temperature drops below
0°C, and the water heater is switched off the tank of the appliance has to be
emptied.
All the above operations are not covered by the warranty service, the work must
be performed by the user.