Kospel Luna inox POC.D-5/2 Operating And Installation Instructions Download Page 3

3

ENG-029B/p.351

POC Luna inox - a small storage water heater is suitable for being assembled in a household, a sanitary room, 

a laboratory, a workshop etc.

There are 2 versions of POC Luna inox available: over-(G) and under-the-sink(D).
The water heaters are also available with a tap provided by manufacturer. They will operate as a non-pressure 

appliance; symbols: POC.Gb-5/2 oraz POC.Db-5/2.

POC.Gb-5/2,  POC.Db-5/2

  tap 

set  works  as  an  air  vent  and 

therefore, cannot be connected 

to any valve or a connector that 

is  not  recommended  by  the 

manufacturer.

Purpose

Safety and faultless 

work conditions

-  in order to make use of the appliance it must be properly installed,
-  you must not put the heater on if it is not full with water
-  the appliance should be vented (see 'Venting') before the activation and each time after a decay of water,
-  do not open the heater casing while power is on,
-  the appliance can be connected only to a plug-in socket with a safety pin,
-  an extension cord must not be used to connect the heater with a socket,
-  water at 40

0

C temp. may bring forth the feeling of burning (especially with children); remember that the fit-

tings (e.g. a tap, pipes) also reach high temperature while working,

-  while assembling the POC.G-5/2 or POC.D-5/2 water heater, a safety valve has to be fitted right before the 

appliance on water mains supply pipe; if the water pressure is higher than 0,6 MPa, a pressure reductor has 

to be fitted on the water mains supply pipe before the safety valve,

-  the outlet must not be clogged while water is on and no other appliance should be adjusted to it,

Summary of Contents for Luna inox POC.D-5/2

Page 1: ......

Page 2: ...136 KOSZALIN UL OLCHOWA 1 POLAND This product must not be treated as a communal waste Dismantled appliance ought to be given to an appro priate recycling point for electrical and electronic waste App...

Page 3: ...er on if it is not full with water the appliance should be vented see Venting before the activation and each time after a decay of water do not open the heater casing while power is on the appliance c...

Page 4: ...s a fault it is a normal state of the appliance You mustn t block the pipe as it might cause a malfunction Safety valve as well as the outlet pipe can not be installed in a room with temperatures belo...

Page 5: ...f a hanger 13 tap 14 hanger a b between axes of fixing pins and the tap has to be kept fig 3 2 According to fig 1 or 2 bring the domestic water and the electricity supply to the point where the heater...

Page 6: ...ig 4 Wiring diagram E1 heating box F1 thermal cut out K1 temperature controller XP supplu cord with a plug X1 terminals H1 heating indicator Venting 1 Take the plug out of the socket 2 Open hot water...

Page 7: ...open the hot water 5 Fig 5 Work indicators 1 signal lamp heating on 2 temperature knob In case of a water supply failure lack of water in a system the tap ought to be immediately shut off and a knob o...

Page 8: ...fety class IP24 Water supply pipe section G 3 8 G 1 2 Water heater fittings G 1 2 No Fault Reason Remedies 1 The heater does not heat water A signal lamp does not work Supply power system failure A te...

Page 9: ...sets Hanger 1 pcs 1 pcs 1 pcs 1 pcs Safety Valve 1 pcs 1 pcs This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of exper...

Page 10: ...10...

Page 11: ......

Page 12: ......

Reviews: