EN-045BC_f.1179
11
Number
of impulses
(green indicator)
description
1
The unit was switched off because the temperature has exceeded the
maximum value (fault signal will not disappear until the appropriate rate of
water flow is reached).
2
The unit was switched off by a master appliance.
3
The inlet temperature sensor failure.
4
The unit was switched off because the air bubbles in the heating box (the
unit will not heat again until the fault is resolved and the appropriate rate of
water flow is reached).
The heater switches on automatically straight after reaching the flow rate over
2,5l/min. The temperature control system adjusts the power rate according to the water
flow rate, required temperature and the water temperature in the mains.
There are two indicators on the case:
-
green - power supply „on”,
-
red - heating „on”.
Other modes are shown by flickering green light.
KDE, KDE2 Operation