background image

6

Heater’s deactivation

In order to deactivate the heater follow procedure below:

turn off the electric power supply,

make sure that the heater is cold,

while holding device’s case, loosen the screws on both sides of heater’s hanger 

(it is recommended to cooperate with another person during this procedure); 

if the hanger can be replaced from the wall- undo the screws and replace it, 

cover the heater with shock-absorbant material before packing,

in  case  you  need  help  with  device’s  deactivation-contact  closest  authorised 

service.

Type

IH 1,5

IH 2,0

Rated power

W

1500

2000

Rated voltage

V

230V 1N~

Rated current

A

6,52

8,69

Dimensions

mm

500 x 119 x 104

Weight

kg

2,20

Min. distance from the floor

mm

2,10

2,50

Degree of protection

IP55

Technical data

Reflector’s cleaning

When it is necessary to clean the reflector, follow the procedure below:

switch off electric power supply,

ensure that the heater is cold,

take off front protective fence,

clean the reflector with a dry cloth,

do not touch the lamp with bare hands during the cleaning procedure; however, 

if the lamp gets dirty, clean it with a soft cloth soaked in alcohol,

re-install the front protective fence,

turn electric power supply on.

Summary of Contents for IH 1,5

Page 1: ...IH 1 5 IH 2 0 Infrared Heaters Assembly and operating manual...

Page 2: ...hysical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safe...

Page 3: ...B 077B 1 2 3 4 5 6 7 155mm 119mm 500mm Product components 1 Protective fence 2 Quartz lamp holders and quartz lamp 3 Reflector 4 Hard case 5 Side Caps 6 Electric cable 7 Wall hanger 8 Installation scr...

Page 4: ...fter plugging its cable to the electrical socket Description According to Laws of Thermodynamics there are three types of heat transfers conduction convection radiation The so called radiant heaters f...

Page 5: ...hin at least 1 25 m distance from the heater 7 Prolonged looking at the lamp may cause sight damage While the heater is on avoid looking at the lamp 8 The device should be protected from vibrations an...

Page 6: ...ntact closest authorised service Type IH 1 5 IH 2 0 Rated power W 1500 2000 Rated voltage V 230V 1N Rated current A 6 52 8 69 Dimensions mm 500 x 119 x 104 Weight kg 2 20 Min distance from the floor m...

Page 7: ...pment for recycling Appropriate utilisation of used product prevents potential negative environmental influ ences that may occur as a result of inappropriate handling of waste In order to get more det...

Page 8: ...KOSPEL S A 75 136 Koszalin ul Olchowa 1 tel 48 94 31 70 565 serwis kospel pl www kospel pl...