6
Heater’s deactivation
In order to deactivate the heater follow procedure below:
-
turn off the electric power supply,
-
make sure that the heater is cold,
-
while holding device’s case, loosen the screws on both sides of heater’s hanger
(it is recommended to cooperate with another person during this procedure);
-
if the hanger can be replaced from the wall- undo the screws and replace it,
-
cover the heater with shock-absorbant material before packing,
-
in case you need help with device’s deactivation-contact closest authorised
service.
Type
IH 1,5
IH 2,0
Rated power
W
1500
2000
Rated voltage
V
230V 1N~
Rated current
A
6,52
8,69
Dimensions
mm
500 x 119 x 104
Weight
kg
2,20
Min. distance from the floor
mm
2,10
2,50
Degree of protection
IP55
Technical data
Reflector’s cleaning
When it is necessary to clean the reflector, follow the procedure below:
-
switch off electric power supply,
-
ensure that the heater is cold,
-
take off front protective fence,
-
clean the reflector with a dry cloth,
-
do not touch the lamp with bare hands during the cleaning procedure; however,
if the lamp gets dirty, clean it with a soft cloth soaked in alcohol,
-
re-install the front protective fence,
-
turn electric power supply on.