16
Technical data
EKP.LN2M
11
13
18
24
Rated power
kW
11
13.2
18
24
Rated voltage
230V~
400V 3N~
Rated current
A
52.2
57.5
3x26.3 3x34.6
Min. connecting wires section
mm
2
3x16
5x4
5x6
Max. connecting wires section
mm
2
3 x 25
5 x 25
The maximum allowed network
impedance
Ω
0.24
0.22
0.27
0.13
Water heater
Efficiency (at Δt = 30°C and water
pressure at 0,4 MPa)
l/min
5.3
6.3
8.7
11.6
Pressure in the water mains
MPa
0.1 ÷ 1.0
Activation point (min. rate of flow)
l/min
2,5
Temperature adjustment range
°C
30 ÷ 60
Water fittings
ø
15mm
(connections position 50mm)
The minimal resistivity of water 15
0
C
Ωcm
1100