26
Start-up
With the first start-up of the boiler or after restoring to factory settings it is necessary
to select the language and boiler’s rated power. the boiler is ready to work properly only
after selection of these parameters.
In daily schedule CH circuit and DHW cylinder have defined starting time (3) and finishing
time (4) of maintaining selected temperature value (5) in the room (CH) or DHW cylinder.
Outside defined time frames economy temperature will be maintained in the room/cylinder.
For circulation circuit within the schedule there is an adjustment of start time (3) and
finish time (4) of circulation pump’s operation. In buffer mode there is an adjustment of
start time (3) and finish time (4) of buffer’s charging. To change the parameters for the
daily schedule select chosen program number and press navigation dial.
The first parameter flashes (start time) - use the navigation dial to set the new time
frame value (hour and minutes separately) by turning the dial left/right and confirm it by
pressing the dial again. At the same time next screen starts to flash allowing edition of next
parameters (finish time). Last editable position is a command. In order to save changes
select command „save” and press the dial
to finish editing. To delete selected time
frame start editing chosen time frame and by pressing the dial go to command position,
select command „delete” and press the dial
. To add new time frame, select last defined
time frame and by pressing the dial go to command position, select command „add” and
press the dial
to add new time frame (edition of new time frames described above) .
Daily schedule:
CH program No1
CH program No1
1 6:00 - 9:15
2 15:20 - 22:15
2 15:20 - 22:15
2
3
4
5
6
1
End
End
1 - time period panel
2 - no. of time frame according to schedule
(max 5)
3 - start time
4 - finish time
5 - temperature selection (CH and DHW cylinder)
6 - command (active when editing):
accept
delete
add
Summary of Contents for EKCO.M3