Service Manual
20
13. Technical data.
Max.pressure
MPa
0,3
Min.pressure
MPa
0,05
Outflowing water temp.
°C
40 ÷ 85 (30 ÷ 60)*
Max. water temp.
°C
100
Overall dimensions
mm
EKCO.L1 660 x 380 x 175
EKCO.L1N 700 x 425 x 285
Weight
kg
EKCO.L1 ~16
EKCO.L1N ~24
Water connection
G 1/2"
Expansion vessel (in EKCO.L1Nz only)
l
6
Safety class
IP 21
Boiler type
EKCO.L1Fz, EKCO.L1NFz
4
6
8
6
9
12
14,4
Rated power consumption
kW
4
6
8
6
9
12
14,4
Rated voltage
230V~
240V~
Rated current
A
17,4
26,0
34,8
25
37,5
50
60
Fuse rated current
A
20
32
40
32
50
63
80
Min. connecting wires section
mm
2
3 x 2,5
3 x 4
3 x 6
3 x 2,5
3 x 6
3 x 10
Max. connecting wires section
mm
2
3 x 16
3 x 25
Boiler type
EKCO.L1z, EKCO.L1Nz
4
6
8
12
15
18
21
24
Rated power consumption
kW
4
6
8
12
15
18
21
24
Rated voltage
400V 3N~
Rated current
A
3 x 5,7
3 x 8,7
3 x 11,7
3 x 17,3
3 x 21,7
3 x 26,0
3 x 30,3
3 x 34,6
Fuse rated current
A
10
16
20
25
32
40
Mini. connecting wires section
mm
2
5 x 1
5 x 1,5
5 x 2,5
5 x 4
5 x 6
Max. connecting wires section
mm
2
5 x 16
*Relates to EKCO.p for underfloor heating
Table 5
Copiled by Paweł Wojtanowski
Copyright Kospel S.A.