3.1

 

Dehumidification Running 

 

1.

 

When the compressor has passed the protection for 3 minutes and the indoor humidity ≥ set hu 5% RH, 

the compressor will work again. 

 

2.

 

When the indoor humidity < set humidity - 5% RH, the compressor is turned off. 

 

3.

 

Set the humidity - 5% RH < indoor humidity < set hu 5% RH to keep the original compressor working. 

 

4.

 

The compressor stops the fan if it has not been operated for three minutes after the humidity has dropped. 

 

5.

 

When  the  machine  beeps  three  times  and  the  water  full  indicator  light  is  on,  the  machine  stops  working. The 

water in the water tank needs to be drained and the water tank is reinstalled. If the water full indicator light is still 

on, check whether the water tank is in place. The operation is started until the water full indicator is off. 

 

6.

 

Defrost 

 

A)

 

After  the  machine  starts  to  run  for  30  minutes,  the  copper  coil  sensor  starts  to  detect  the  tube  temperature. 

When the tube temperature is ≤ -1 °C (there is 3 seconds of detection time), the compressor stops and the fan runs, 

and the defrosting operation starts. The lights are shining. 

B)

 

When  the  temperature  sensor  detects  that  the coil  temperature  on  the  evaporator  is greater  than or  equal  to 5 

degrees and the detection is greater than or equal to 5 degrees for 3 minutes, the defrosting is exited. 

 
 

 

3.2

 

Drain Indicator 

 

Water level float 

 

Do not remove the float from the tank. If the float in the tank is removed, the machine will not turn on or start. 

 

Put water tank back. 

 

When placing  in  the water  tank, push the water  tank into the machine with both hands and put it in place. If the 

water  tank  is  not  put  in  place,  the  machine  will  not  be  able  to  start  or  turn  on  the  water  after  the  operation,  the 

machine will overflow. 

Clean the water tank 

 

If the water tank is dirty, clean it with  cold/warm  water. Do  not  use detergent, steel ball,  chemically  treated dust 

cloth, gasoline, benzene, thinner or other solvents as it may damage the water tank. 

Summary of Contents for KM-20N

Page 1: ...Household Dehumidifier User Manual KM 20N www kosmen vn...

Page 2: ...ion of the Button 2 2 1 Operation 2 2 2 Indicator Lights 2 3 Operating Instructions 4 3 1 Dehumidification Running 5 3 2 Drain Indicator 5 4 Maintaining 7 4 1 Cleaning 7 4 2 Placing 7 5 Specification...

Page 3: ...quan tr ng 10 2 C c n t ch c n ng 11 2 1 V n h nh 11 2 2 n b o 12 3 H ng d n v n h nh 13 3 1 Ch y m y h t m 14 3 2 n b o tho t n c 14 4 B o tr 16 4 1 V sinh 16 4 2 L p t 16 5 Th ng s k thu t 17 6 M l...

Page 4: ......

Page 5: ...mine the cord carefully Make sure that it is not punctured or frayed Inspect the plug to ensure that the prongs are secure and the plastic surrounding it is not cracked Never use the plug to start and...

Page 6: ...every press TIMING Press the Timer button the timing indicator lights up in green the timing time can be adjusted in 1 24 hours and then press the Timer button until the display shows 00 After eight...

Page 7: ...f humidity and wind speed is invalid 2 2 Indicator Lights POWER ON OFF When the power cord is plugged in the machine display shows the current ambient humidity Press the power button the power indicat...

Page 8: ...ly available on KM 20N and KM 60S 3 Operating Instructions When the appliance is powered on for the first time the appliance enters the standby state press the power button to enter the running state...

Page 9: ...ensor starts to detect the tube temperature When the tube temperature is 1 C there is 3 seconds of detection time the compressor stops and the fan runs and the defrosting operation starts The lights a...

Page 10: ...c tube 11mm inside through which water can be drained When using a water pipe do not immerse the water outlet in the water to prevent the pipe from being too long or the pressure is formed in the pipe...

Page 11: ...he surface of the machine Remarks Clean the carbon filter twice a month to ensure a healthy environment and energy saving When the dehumidifier is working make sure the Minimum distance between air in...

Page 12: ...Net Weight 10 5 KGS 6 Error Code Fault Code The failure How to do with it E1 Temperature sensor breakdown Replace with new temperature sensor E2 Humidity sensor breakdown Replace with new humidity se...

Page 13: ...e 2 The front and back of the dehumidifier may be blocked 3 Dehumidification time may be not enough 4 Door and window may be open 5 The temperature indoor is lower than 5 or higher than 38 1 Set appro...

Page 14: ...r i r t Ki m tra d y i n c n th n tr nh t nh tr ng b th ng ho c s n Ki m tra ph ch c m m b o r ng c c u c m ch c ch n v l p nh a bao quanh kh ng b n t Kh ng c r t ph ch c m i n kh i ng ho c t t m y ph...

Page 15: ...v 40 70 i u ch nh 10 m t l n n TIMING n n t Timer n t b o th i gian s ng l n m u xanh c th i u ch nh th i gian trong 1 24 gi sau nh n n t Timer cho n khi m n h nh hi n th 00 Sau t m l n nh p nh y m n...

Page 16: ...g m v t c gi c i u khi n t ng b i m y h t m v kh ng th i u ch nh m v t c gi 2 2 n b o B T T T NGU N Khi c m d y ngu n m n h nh m y hi n th m m i tr ng hi n t i Nh n n t ngu n n b o ngu n s s ng m u xa...

Page 17: ...c Ch t ch h p v i KM 20N v KM 60S 3 H ng d n v n h nh Khi kh i ng l n u ti n m y s tr ng th i ch nh n n t ngu n chuy n sang tr ng th i ch y b t ngu n v kh i ng u ti n l ch h t m li n t c ng c ch y t c...

Page 18: ...nhi t ng Khi nhi t ng 1 C trong v ng 3 gi y m y n n d ng qu t ch y v ho t ng x b t u n ang s ng D Khi c m bi n nhi t nh n th y nhi t cu n d y tr n thi t b l n h n ho c b ng 5 trong v ng 3 ph t qu tr...

Page 19: ...n i v i nhau b ng m t ng nh a 11mm b n trong tho t n c qua Khi s d ng ng n c kh ng c nh ng u tho t n c v o trong n c tr nh tr ng h p ng qu d i ho c t o p l c trong ng khi ng tho t n c b t c D n n d ng...

Page 20: ...Ch V sinh m ng l c hai l n m t th ng m b o m ng l c s ch v ti t ki m n ng l ng Khi m y h t m ang ho t ng h y ch c ch n m b o kho ng c ch t i thi u gi a c a h t gi v b c t ng l 20 cm Kho ng c ch t i t...

Page 21: ...x th i 3L K ch th c s n ph m 320 214 537 mm Tr ng l ng s n ph m 10 5 KGS 6 M l i M l i L i C ch kh c ph c E1 S c c m bi n nhi t Thay th b ng c m bi n nhi t m i E2 S c c m bi n m Thay th b ng c m bi n...

Page 22: ...c u 1 C i t m kh ng ph h p 2 M t tr c v m t sau c a m y h t m c th b c n tr 3 Th i gian h t m c th kh ng 4 C a ra v o v c a s ang m 5 Nhi t trong nh th p h n 5 ho c cao h n 38 1 C i t m th ch h p 2 L...

Page 23: ......

Page 24: ...iep Binh Phuoc Thu Duc City Ho Chi Minh City Vietnam Ha Noi office No 3 Lane 495 Nguyen Trai Thanh Xuan Nam Ward Thanh Xuan District Ha Noi City Vietnam Da Nang office No 385B Hai Phong Tan Chinh Ward...

Reviews: