Korenix JetNet 3705-24V User Manual Download Page 8

 

5

 

 

LED Indicators 

 

The diagnostic LEDs located on the front panel of the industrial switch provide real-time 

information of system and operation status. 

Table-1

 provides the description of the LEDs 

status and their definitions for the switch. 

 

LED 

Color 

Description  

On 

Power input 1 is active 

P1 Green 

Off 

Power input 1 is inactive 

On 

Power input 2 is active 

P2 Green 

Off 

Power input 2 is inactive 

On 

Power input 1 or 2 has failed 

P-Fail Red 

Off 

Power input 1 and 2 are both functional, or no power 

inputs 

On 

The port is supplying power to the powered-device 

PoE indicator 

(Port 1 ~ 4) 

Green 

Off 

No powered-device attached or power supplying fails 

On 

Connected to network 

Flashing 

Networking is active 

Green 

  Off 

Not connected to network 

On Full-duplex 

link 

Flashing Collision 

occurs 

LAN Port 1 ~ 5 

(RJ-45) 

Amber 

 

Off 

Half-duplex link or link down 

Table-1: LED Indication Definition 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for JetNet 3705-24V

Page 1: ...JetNet 3705 24V 5 port Industrial Fast Ethernet PoE Switch User Manual Revision V1 0...

Page 2: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Page 3: ...Front Panel 4 Top View 4 LED Indicators 5 Ports 6 Cabling 7 Wiring the Power Inputs 8 Wiring the Fault Alarm Contact 9 Mounting Installation 10 DIN Rail Mounting 10 Wall Mounting 11 Hardware Installat...

Page 4: ...4 ports 15 4w power consumption With the rugged Aluminum alloy housing the JetNet 3705 24V survived under 25 C 60 C environment temperature give your Power over Ethernet application best reliability...

Page 5: ...checklist JetNet 3705 24V User manual Removable Terminal Block installed on the device Wall mount Kit 2 wall mount bracket with screws Compare the contents of the industrial switch with the standard...

Page 6: ...ndustrial switch s hardware specs ports cabling information and wiring installation will be described Physical Dimension JetNet 3705 24V dimensions W x D x H is 48 6mm x 95mm x 140mm the detail dimens...

Page 7: ...Front Panel of the PoE Injectors Industrial Switch Top View The top view of the JetNet 3705 24V has one terminal block connector of two DC power inputs and Relay circuit contact Please refer to Figur...

Page 8: ...er input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 has failed P Fail Red Off Power input 1 and 2 are both functional or no power inputs On The port is supplying power to...

Page 9: ...on this industrial switch supports automatic MDI MDI X operation users can use straight through cables See figures below for all network connections to PCs or Servers or to other switches hubs In stra...

Page 10: ...witch Switch 3 TD 3 RD 6 TD 6 RD 1 RD 1 TD 2 RD 2 TD Figure 5 Crossover Cable Schematic Cabling Twisted pair segments can be connected with unshielded twisted pair UTP or shielded twisted pair STP cab...

Page 11: ...on the terminal block connector as shown in Figure 6 Figure 6 Terminal Block Front View for Power1 Power2 Contact 2 Tighten the wire clamp screws which as shown in the Figure 7 for preventing the wire...

Page 12: ...e refer to Figure 8 for the fault alarm contact and Figure 9 shows the application example for the fault alarm operation Figure 8 Terminal Block Front View for Fault Alarm Contact Figure 9 Fault Alarm...

Page 13: ...on line in the factory If the bracket is not screwed on the switch please refer to Figure 10 to screw it on the switch Follow the steps below to hang the industrial switch Figure 10 Rear side of the P...

Page 14: ...teps above Wall Mounting Please refer to Figure 12 and follow the steps below to mount the industrial switch with wall mount bracket and the detail dimension of the bracket as Figure 13 1 Remove the D...

Page 15: ...12 Figure 12 Wall Mount Bracket Installation Figure 13 Wall Mount Bracket Dimension...

Page 16: ...IN Rail or wall please refer to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the...

Page 17: ...Switch 14 Network Application This segment provides the sample to help user have more actual idea of industrial switch application For a sample application of the industrial switch see the Figure 14 b...

Page 18: ...Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the Switch can be easily monitored thro...

Page 19: ...880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX Fast Ethernet port MAC Address 2K MAC address table Connector 10 100TX 5 x RJ 45 Power P Fail 1 x 6 poles Removable Terminal Block PoE Pin...

Page 20: ...umption 62 5 Watts 48V 67 Watts 24V Full load with PoE function Installation DIN Rail mounting Wall mounting Operating Temp 25o C to 60o C standard model Operating Humidity 5 to 95 Non condensing Stor...

Page 21: ...strategy focuses on establishing and developing trustworthy relationships with value added distributors and channel partners and assisting OEM distributors to promote their own brands Korenix supplie...

Reviews: