![Korenix JetNet 3008 User Manual Download Page 24](http://html1.mh-extra.com/html/korenix/jetnet-3008/jetnet-3008_user-manual_1997827024.webp)
Tx Power range: -20 dBm (Min.) ~-14 dBm (Max.)
Rx Sensitivity:-31 dBm (Max.)~0 dBm (Min.)
Link Budget: 11dB
JetNet 3008f-s, 30KM
Wave-length: 1310 nm
Tx Power:-15 dBm (Min.)~-8 dBm (Max.)
Rx Sensitivity:-34 dBm (Max.)~-8 dBm (Min.)
Link Budget: 19 dB
Diagnostic LED
Per system: Power (Green) x2
10/100TX port: Speed (Yellow on/ 100Mbps ,Yellow
off/10Mbps), Link/Activity (Green on/ Green blinks)
Alarm: Port /Power Event (Red on)
Power Requirements
System Power
2 Power inputs with redundancy and polarity reverse
protection
Voltage: DC 24V (12~48V).
Power Consumption
JetNet 3008: 8 Watts @ DC 24V
JetNet 3008f: 12 Watts @ DC 24V
Mechanical
Installation
DIN-Rail mount
Case
IP-31 grade aluminum metal case
Dimension
120mm(H) x 55mm (W) x 108mm (D) ( with DIN rail
clip)
Weight
0.775kg with package
0.525kg without package
Environmental
Operating Temperature
JetNet 3008: -25
~
℃
70
℃
JetNet 3008f: -10
~
℃
70
℃
Operating Humidity
0% ~ 95%, non-condensing
Storage Temperature
-40
~ 8
℃
5
℃
Storage Humidity
5%~ 90%, non-condensing
Regulatory Approvals
EMI
FCC class A, CE/EN55022 class A.
EMS
CE/EN61000-4-2, CE/EN61000-4-3
CE/EN61000-4-4, CE/EN61000-4-5
CE/EN61000-4-6, CE/EN61000-4-8
Shock
IEC60068-2-27
Vibration
IEC60068-2-6
Free Fall
IEC60068-2-32
MTBF
400,000hours *MIL-HDBK-217F GB(MILITARY
HANDBOOK) standard
Warranty
Global 5 years