background image

10

8.38

 [212.8]

7.62

 [193.5]

9.45

 [240.0]

 THERMOST

A

T

TEMPERA

T

URE ALARM

TERMINAL

 BLOCK

POWER

SUPPL

Y

 *HOOKS

 *NOTE: (2) HOOKS 

ARE MOUNTED 

T

O

 THE UNIT

 BY

 CUST

O

MER

4.66

 [1

18.3]

 3.32

 [84.3]

18.44

 [468.3]

5.90

 [149.8]

 2.54

 [64.5]

 1.66

 [42.1]

 5.06

 [128.5]

15.10

 [383.5]

.63

 [16.0]

7.58

 [192.5]

 7.75

 [196.8]

 TYP

.

5.96

 [151.3]

  

TYP

.

 27.94

 [709.6]

 .66

 [16.8]

4.00

 [101.6]

 TYP

.

13.54

 [343.9]

 TYP

.

11

.7

9

 [299.4]

2.75

 [70.0]

  

TYP

.

3.96

 [100.5]

1.1

1

 [28.1]

3.07

 [78.0]

 2.64

 [67.0]

 10.37

 [263.3]

 1.59

 [40.3]

8.76

 [222.5]

DRAIN

TUBE

5.83

 [148.0]

1.48

 [37.5]

1

2

2

3

4

2

2

Drawings and Dimensions (con’t)

K3NA4C4SP28L

Dimensions

, inches [mm], are f

o

r ref

e

rence only and are subject to change

.

FILTERED CONDENSER AIR INLET (Ambient Air In)

CONDENSER OUTLET (Warm Ambient Air Out)

WARM AIR RETURN FROM ENCLOSURE

COOL AIR OUTLET  TO ENCLOSURE

1

2

3

4

GA202528A

Summary of Contents for Slimkool K3NA4C4SP28L

Page 1: ...IS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com 900 039 81 1 19 CDR 20131 SLIMKOOL SERIES K3...

Page 2: ...c model page of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtual...

Page 3: ...prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection...

Page 4: ...H Cooling BTU H Max Ambient Temperature Min P S I G P S I G Design Pressure Low Side Design Pressure High Side Oz Factory Charge Refrigerant Max Fuse Size HACR Type Circuit Breaker Min Circuit Ampacit...

Page 5: ...n discharged to the environment When the Kooltronic Air Conditioner is properly sized it should operate constantly and maintain 75 F to 115 F enclosure temperature depending on the ambient temperature...

Page 6: ...the new set point value push the SET key again or wait 10 seconds HOW TO CHANGE A PARAMETER VALUE To change a parameter s value operate as follows 1 Enter the Programming mode by pressing the SET plu...

Page 7: ...p code 7 0 65535 rEL Software release 0 rSE Real set point 0 onF on off key enabling ES PbC Kind of probe ntc Adr Serial address 1 1 247 HES Differential for energy saving 0 F 54 54 rrd Regulation res...

Page 8: ...trical power on 4 Verify that the evaporator blower or fan is running 5 Observe the temperature on the digital display The thermostat must be set a minimum of 10 F below this temperature for the compr...

Page 9: ...m are for reference only and are subject to change WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE 1 2 Mounting con t 1 These externally mounted air conditioners have pre installed gaskets...

Page 10: ...3 TYP 27 94 709 6 66 16 8 4 00 101 6 TYP 13 54 343 9 TYP 11 79 299 4 2 75 70 0 TYP 3 96 100 5 1 11 28 1 3 07 78 0 2 64 67 0 10 37 263 3 1 59 40 3 8 76 222 5 DRAIN TUBE 5 83 148 0 1 48 37 5 1 2 2 3 4...

Page 11: ...36 01 Transformer 0932 38 Fuses 2 0916 30 Phase Protector 0694 73 Overload 0694 72 Overload base 0694 74 Filter 9501F SLIMKOOL NEMA 4X model offered with these additional features Stainless Steel Shel...

Page 12: ...or threshold setting and the compressor will continue to cycle on and off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter and conden...

Page 13: ...lity They are designed to require only routine maintenance If your air conditioner should require warranty service please contact Kooltronic If you require service out of warranty we have compiled a t...

Page 14: ...difference between return and Coil clogged supply air is less than 10 F Evaporator Blower Condenser Loss of Refrigerant Locate and repair leak Blower and Compressor are running Ice on Evaporator Coil...

Page 15: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...