II. Incoming Inspection

Kooltronic Heat Exchangers are designed, built, and packaged to withstand the shock and vibration nor-
mally associated with shipment by common carriers. Occasionally improper handling during shipping caus-
es damage. Such handling could include unbanding of palletized shipments, failing to respect any carton
handling instructions, falling off conveyors, excessive vibration, crushing, etc. Therefore, a thorough inspec-
tion should be done upon receipt of all shipments. Any carton tears, dents, scratches, or loose articles should
be noted on the Freight Bill. Cartons should be opened promptly and the units inspected for CON-
CEALED DAMAGE.

An immediate claim MUST be filed with the freight carrier and an inspection requested. Retain all
packing materials. Kooltronic cannot assume responsibility for Consignee’s failure to file a timely freight claim.

III. Product Handling

Do not attempt to operate your Kooltronic Heat Exchanger until you read and thoroughly understand
this Manual.

Before operating this unit, all electrical wiring must be checked to assure the proper connections.

IV. Product Identification and Nameplate

Each Kooltronic Air Conditioner includes an identification nameplate. This nameplate provides:

CAUTION

Operate this unit only on the proper voltages and frequencies as noted on the nameplate.

MODEL NO.

SERIAL NO.

MAX. CABINET

VOLTS.

FREQ.

PH.

AMPS

TEMP. 

o

F

MAX.

FUSE SIZE

UNAUTHORIZED SERVICE OR MODIFICATION VIOLATES WARRANTY

ALL MOTORS ARE THERMALLY PROTECTED

THIS PRODUCT IS PROTECTED BY ONE OR MORE OF THE FOLLOWING
PATENTS: 3,019,965  3,120,166  3,211,360  3,559,728  3,807,493  AND 
OTHER PATENTS PENDING

MANUFACTURED BY:

KOOLTRONIC, INC.  PENNINGTON, NJ

Heat Exchanger

➂     

Model Number

Serial Number

Electrical power characteristics

Maximum ambient operating temperature

We recommend you copy this information from 
your unit.

➀➁ 

When ordering parts, specify the Model

Number and Serial Number.

➂ 

Before operating, be sure that the 

power source matches these requirements.

Make sure that these parameters are met.

Failure to do so may result in permanent 
damage to the unit.

Summary of Contents for KNHE30 Series

Page 1: ...AT EXCHANGER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com 900 046 20 7 20 CDR 20272 Find additional information on this model at kooltronic com or use the Technical Documents QR code below Technical Documents ...

Page 2: ...ntroduction Kooltronic Heat Exchangers are designed to provide a cool environment for your electronic or electrical components There are models to fit virtually all sizes and shapes of electrical or electronic enclosures Our closed loop design also ensures that your components will not be exposed to hot dirty operating conditions This Manual provides you with the necessary general information for ...

Page 3: ...ger until you read and thoroughly understand this Manual Before operating this unit all electrical wiring must be checked to assure the proper connections IV Product Identification and Nameplate Each Kooltronic Air Conditioner includes an identification nameplate This nameplate provides CAUTION Operate this unit only on the proper voltages and frequencies as noted on the nameplate MODEL NO SERIAL ...

Page 4: ...ipated conditions In some cases if sufficiently cold water is available below ambient temperature cooling can be achieved The Heat Exchanger with options Automatic Water Flow Control is shown on Figure 2 Heated Air Blower Water with Heat Load Cold Water Heat Exchanger Cabinet Cooled Air WATER TO AIR A Water to Air Heat Exchanger works by transferring heat of internal air to circulating water resul...

Page 5: ...he bottom of the unit This hose must not be elevated above the exit port Improper mounting will impede the flow of condensate and may cause internal malfunctions 7 Attach supply line to 1 2 O D copper tubing Inlet on bottom of unit 8 Attach discharge line to 1 2 O D copper tubing Outlet on bottom of unit 5 Dimensions inches metric are for reference only and are subject to change MOUNTING PLAN FIGU...

Page 6: ...nishes Special motors line cords or connectors Temperature Alarm WE RED WATER LEVEL ALARM WE BK HIGH TEMPERATURE ALARM TO CUSTOMER ALARM SYSTEM TERM BLOCK HEAT AND WATER ALARM BK RD WE A BLACK H THERMOSTAT N C N O COM N C N O COM 1 2 3 4 5 6 7 8 N O BK LEVEL SWITCH CIRCUIT SHOWN WITH LINE POWER OFF NO NC BK RD WE TO CUSTOMER S LOW AIR FLOW ALARM SYSTEM THERMOSTAT SOLENOID CAPACITOR BLOWER MOTOR BR...

Page 7: ...e listing of Major Component Replacements earlier in this manual VIII Packing Procedure Keep Heat Exchanger in proper upright position Pack Heat Exchanger in an appropriate carton preferably original carton if possible with adequate internal protective packaging making sure carton is marked properly For local controlled transportation strap carton where possible to a secure part of truck to preven...

Page 8: ...s received by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a suitable container for shipment preferably the original packaging if available All Heat Exchangers must be returned in an upright position properly secured to a pallet Improper packaging may void wa...

Reviews: