C. Compressor

All Kooltronic compressors are approved by UL and CSA, and require no maintenance. They are
hermetically sealed and charged at the factory, and equipped with automatic-reset thermal overload
protectors.

If the compressor or the hot gas bypass valve fails, it is strongly recommended that the air conditioner be
returned to Kooltronic for service.

D. Refrigerant Loss

Kooltronic Air Conditioners are subjected to a series of tests to detect refrigerant leaks, during and after
manufacture. It is possible that shipping or other damage, or microscopic leaks over a long period, may
result in the need for replenishment of refrigerant charge.

When it has been verified by a qualified

professional that a refrigerant shortage does exist, the leak must be repaired. Then the unit may be
evacuated and recharged in the field by qualified service people only.

CAUTION

E. Relocation

If your Kooltronic Air Conditioner has to be moved to another location by truck, the following precautions
should be taken:

I

De-mount Air Conditioner from equipment, controller or enclosure.

I

Conform to the applicable provisions of PROCEDURE FOR PROPER PACKING AND
SHIPMENT OF KOOLTRONIC AIR CONDITIONERS in this manual under 

Section III.

"PRODUCT HANDLING".

Refer to the data on the unit nameplate which specifies the type of

refrigerant and the amount of charge in ounces. 

.

IX. Trouble-Shooting

Each Kooltronic Air Conditioner is engineered for performance and built for reliability. They are designed to
require only routine maintenance. If your air conditioner should require warranty service, please
contact Kooltronic. If you require service out of warranty, we have compiled a trouble-shooting chart
to assist your service personnel. If additional assistance is required contact Kooltronic at (609) 466-3400

.

Problem

Cause

Solution

Unit does not run.

No Power.

Check Power Source and electrical connection.
Check unit ON-OFF switch (UL Listed units only).
Check unit power cord connection to terminal block.

After initial 15 minute energization

Return temperature is

Normal Operation.

of air conditioner, compressor and

between Thermostat set

Check return air temperature. 

condenser fan do not run.

point and differential

Check sensor connection on Thermostat.

(

75°F to 86°F).

Summary of Contents for K2A6C12HTL

Page 1: ...S MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com 900 039 66 1 19 CDR 20131 LARGE HORIZONTAL TO...

Page 2: ...the specific model page of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to...

Page 3: ...s prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connectio...

Page 4: ...e that the power source matches these requirements y Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met...

Page 5: ...mostat to prevent the evaporator coil from freezing In conditions of low ambient temperature and low enclosure load the thermostat regulates the return air temperature from 75 F to 86 F The standard s...

Page 6: ...ning after three 3 to five 5 minutes 7 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evaporator and condenser...

Page 7: ...lets and outlets is essential for optimum performance of the Air Conditioner Place supplied gasket on perimiter of enclosure cutouts All externally mounted Air Conditioners must be fully gasketed to e...

Page 8: ...to change 2 06 52 3 17 4 3 2 60 66 0 2 1 1 2 4 3 J2 3 4 5 10 9 8 7 6 1 2 3 J1 CG RELAY CONTACTS N O 240 VAC 120 VAC TEMPERATURE SENSOR Mounting Holes 4 156 3 9 DIA ADJUSTING PINS 3 2 1 4 70 F Connect...

Page 9: ...6 8 1 17 29 7 31 08 789 4 70 17 7 16 15 410 2 12 90 327 6 3 62 91 9 15 83 402 0 12 32 312 9 87 22 0 1 2 3 4 Drawings and Dimensions con t K2A6C12HTL Dimensions inches mm are for reference only and are...

Page 10: ...12HTL Part Part Number Compressor 0665 401 Compressor Run Capacitor 0452 54 Condenser Motor 0261 80 Condenser Motor Capacitor 0452 06 Evaporator Impeller 0194 15 Evaporator Impeller Capacitor 0452 73...

Page 11: ...the filter clears the upper filter retainer 2 After removal the filters should be flushed under warm running water with the clean side up driving contaminants out the dirty side of the filter If the...

Page 12: ...onditioner from equipment controller or enclosure I Conform to the applicable provisions of PROCEDURE FOR PROPER PACKING AND SHIPMENT OF KOOLTRONIC AIR CONDITIONERS in this manual under Section III PR...

Page 13: ...or and Evaporator Blower Check Blower Capacitor are running Condenser Blower does Replace Condenser Blower not run Failed Condenser Blower Replace Condenser Blower Thermostat Thermostat or Sensor Repl...

Page 14: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Reviews: