Standard Features

Available in either top or bottom evaporator
air discharge models
Baked Powder Finish
Closed-Loop Cooling
Condenser Blower Speed Controller
Crankcase Compressor Heater
Heavy-duty Steel Shell
Low Temperature Control Thermostat
NEMA 3R, 12 &1 Ratings Maintained (UL50)
Tamper-resistant hardware
UL Recognized
Zero ODP Refrigerant

Accessories and Options

Enclosure Heater
Internal Corrosion Protection
Lead-Lag Controller
Remote Thermostat Relay
Special materials or finishes 
Temperature Alarm

Technical Data

Mode

l

BTU/H
Rating

95/95

Rating
BTU/H

Ambient

Temp. ºF

Max./Min. Volts

Hz

Cooling

Amps

Heating

Amps

Approx.

Weight

(lbs)

K2A3C30EP56TR
K2A3C30EP56BR

K2A6C30EP56TR
K2A6C30EP56BR

30000
30000

30000/24000
30000/24000

26000
26000

28000/22000
28000/22000

131/0
131/0

131/0
131/0

230
230

230
230

60
60

60/50
60/50

26.0
26.0

25.5/25.2
25.5/25.2

15.3
15.3

15.3
15.3

302
304

302
304

Major Component Replacements

K2A3C30EP56_R*

K2A6C30EP56_R

Part

Part Number

Part Number

Compressor

0665-57

0665-402

Compressor Capacitor

0452-54

0452-78

Condenser Blower Motor

0261-274

0261-274

Condenser Blower Capacitor

0452-04

0452-04

Evaporator Blower Motor

0261-275

0261-275

Evaporator Coil

0667-51

0667-51

Condenser Coil

0666-45-1

0666-59-01

*NOTE: Part Numbers shown are for 60Hz/1Ø. For 50Hz consult Kooltronic.

Summary of Contents for C20A0647

Page 1: ...OOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com 900 039 39 8 21 CDR 20346 INTREPID EP56 SERIES K2A4C30EP56TR BR Find additional informati...

Page 2: ...onic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of...

Page 3: ...rior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection t...

Page 4: ...that the power source matches these requirements r Make sure that these parameters are met Failure to do so may result in permanent damage to the unit ALL MOTORS ARE THERMALLY PROTECTED VIOLATES WARRA...

Page 5: ...where it absorbs the heat and is then discharged to the environment The unit is equipped with a Low Temperature Thermostat to prevent the evaporator coil from freezing and must not be set below the f...

Page 6: ...the thermostat to its minimum setting turn it counterclockwise The compressor should start On units equipped with a short cycle protector the compressor will have a delayed start of 6 minutes from the...

Page 7: ...in hose to the drain tubing on the bottom of the air conditioner using the plastic clamp CAUTION 7 If the air conditioner is mounted to the cabinet door you must be sure that the door hinges will supp...

Page 8: ...0 POWER CORD 1 1 2 EP56B EP56T 3 4 EP56T EP56B 3 4 57 04 1448 7 DRAIN Drawings and Dimensions EP56 SERIES Dimensions inches metric are for reference only and are subject to change FILTERED CONDENSER...

Page 9: ...ing BTU H Ambient Temp F Max Min Volts Hz Cooling Amps Heating Amps Approx Weight lbs K2A3C30EP56TR K2A3C30EP56BR K2A6C30EP56TR K2A6C30EP56BR 30000 30000 30000 24000 30000 24000 26000 26000 28000 2200...

Page 10: ...mal overload protectors If the compressor fails it is strongly recommended that the air conditioner be returned to Kooltronic for service C Refrigerant Loss Kooltronic Air Conditioners are subjected t...

Page 11: ...ssor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Application Failed Evaporator Blower Replace Evaporator Blower Motor or Assembly Clogged Evaporator Coil Cle...

Page 12: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Reviews: