to figure out damages, if any. In case of any damage detected, please contact us through phone or fax 

immediately, and we will respond to the situation as soon as possible.   

4.3  In  case  of  any damage  or  loss,  please  identify the  situation  in  the  packing  list  and  have  the 

consigner acknowledge it with signature before returning it to us. 

5

Installation 

5.1 The product should be place on a solid and flat floor with no gradient. 

5.2 The product is recommended to work with under 28

 ambient temperature and less than 55% 

relative  humidity,  where  direct  sunshine  and  draught  can  be  avoided.  Additionally,  disturbing  air 

devices such as fan or air conditioner vent should be appear from its top or nearby.   

5.3  Unobstructed  ventilation  should  be  ensured  for  condensing  unit  with  ample  room  for 

repairing. 

5.4  The  melting  water  can  be  directed  into  the  sewer  near  the  product,  if  any,  or  otherwise 

evaporated through electric heating. 

6

Normal operation 

 

6.1 Full-automation. Fully consider the local seasonal conditions within a year and the surrounding 

environment are sufficiently considered during the setting of control modules, to ensure the optimal 

operation of the whole full-automatic product. 

6.2  Normal  cooling.  Set  the  temperature  controller  properly  according  to  customers’  needs  to 

achieve both energy-saving and normal cooling. See the Appendix: Instruction of CAREL Temperature 

Controller for details. 

6.3 Normal melting. Set the timer properly for melting time and interval according to the ambient 

temperature  and  humidity,  with  over  two  melting  periods  for  verification.  See  the  Appendix: 

Instruction of CAREL Temperature Controller for details. 

6.4 Have the customer sign Debugging Record and Installation Acceptance Report before finishing 

the consignment.   

6.5  During  normal  operation,  the  storage  should  not  be  placed  beyond  the  shelf  or  block  the 

return air from the air curtain. 

7

Maintenance and notes 

7.1 Cabinet cleaning. The product should be cleaned once a week with power supply disconnected. 

In cleaning, please use mild rinsing water or non-corrosive cleanser essence. Do not wash it directly 

with water faucet.   

7.2 De-dusting for condenser. The condenser should be cleaned every three months with power 

supply  disconnected.  To  clean  the  condenser,  remove  the  left  panel,  and  remove  the  dust  on  the 

cooling fin of the condenser with wire brush or high pressure air gun.   

7.3 Leaking check. Observe all connectors and welding joints for oil stain, which indicates a must 

for patching measures or call for professionals.   