Koolbreeze KME300 User Manual Download Page 11

Page 11 of 12 

 

Troubleshooting

 

 

Symptom 

Possible Cause 

No Power to Unit 

No power at socket, fuse blown or circuit 
breaker tripped. Move plug to another 
socket, replace fuse or reset circuit 
breaker.  

Cool or humidity function not working 

Water level in unit too low. Refill water 
tank in unit 

Small ‘tweet’ from 

water tank 

Low water level in water tank. Top up 
water level 

Water leaking from vent 

Check cooling pad is correctly installed 

Air not circulating 

Enable 

‘Swing’

 function  

Cooling function button on operator panel 
is RED not GREEN 

Water level in unit is below minimum 
level. Check level and refill if necessary  

 

Technical Information 

 

Technical Specifications 

 

Circuit Diagram 

 

1110 m

3

/Hr 

Summary of Contents for KME300

Page 1: ...Page 1 of 12 Koolbreeze Koolmist 300 KME300 Evaporative Cooling Fan User Guide Please retain these instructions for future reference...

Page 2: ...Maintenance and Cleaning 10 Troubleshooting 11 Technical Information 11 Thank you for purchasing this Koolmist 300 unit Please read the following instructions carefully to ensure proper and safe use...

Page 3: ...being drawn through the unit by the quiet but powerful fan Humidifier Function Reduces dryness of the air Ionizer Function Releases negative ions to freshen the air Detachable and removable components...

Page 4: ...with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understan...

Page 5: ...or Cooling Pad 03 Vertical Swing Louvres 14 Power Cord and Plug 04 Control Panel 15 Water Tank Buckle Catch 05 Top Cover 16 Water Pump 06 Fan Rotor 17 Motor 07 Water Chamber Cover 18 Water Pump Bracke...

Page 6: ...mode is shown by the indicator lights 09 10 and 11 When selected NATURE mode simulates gusts of wind and SLEEP mode reduces intensity over time 04 Timer The unit has a built in timer function When ena...

Page 7: ...d into the remote control 4 Confirm the paper cooling pad and air filter are correctly assembled in the unit 5 Check the power cord for any damage If the power cord is damaged do not use the unit and...

Page 8: ...c plug requirements of the country the unit is being used in either connect the unit to an electricity supply of the correct voltage and type or where necessary remove the supplied converter plug to e...

Page 9: ...Page 9 of 12 8 Operate the unit using the buttons on the remote control or the operator panel...

Page 10: ...ed from the electricity supply 2 The outside of the unit can be cleaned with a damp cloth Do not use abrasive or solvent based cleaning agents to clean the unit 3 The internal water tank can be cleane...

Page 11: ...el in unit too low Refill water tank in unit Small tweet from water tank Low water level in water tank Top up water level Water leaking from vent Check cooling pad is correctly installed Air not circu...

Page 12: ...se in the first instance call the retailer from whom you purchased it Koobreeze Cottage Stores LLP 7 Harris Drive Rugby CV22 6DX United Kingdom Copyright Cottage Stores LLP 2019 All rights reserved Ko...