FAULT-FINDING

If the CLIMATEASY 12NG  is not operating, proceed as 
follows:
Check that the mains plug is firmly in the socket, and that the 
socket is switched ON.
When the unit is switched on there will be a delay of 

up to 3.5 

minutes

 before it starts to operate.

Unit stops running:

Mains supply is disconnected or has failed
Target temperature has been reached.
Timer has been set.
Water tank is full (WATERFULL indicator will illuminate)

In cooling mode, no cool air is produced:

Room temperature is lower than set temperature
The unit is defrosting (this will take a few minutes, and 
afterwards, it will resume operation)
Filter is blocked

Cooling is poor on hot days

Too much direct sunshine is heating the room
Windows or doors are open allowing hot air into the room
A lot of people in the room (each person contributes about 
75W of heating)
Electrical equipment in the room producing heat

Heating is poor on cold days

The heat pump can only heat effectively when the outdoor 
temperature is above 7 °C. The unit is not intended as a 
primary means of heating premises. 

Remote control does not work:

Check batteries are correctly installed, and are not exhausted.
Make sure that the remote control is pointed towards the main 
unit when being used.

Summary of Contents for Climateasy 12NG

Page 1: ...Page 1 Climateasy 12NG Portable Air Conditioner 3 5kW 12000 BTU hour Model Number P12NGP Air Conditioning Heating Cooling Dehumidifying Remote control 3 Fan speeds LED display panel 24 Hour timer ...

Page 2: ...r immediately The appliance contains a refrigerant gas so must be kept upright at all times After unpacking wait 3 hours for the refrigerant gas to stabilise before use INSTALLATION Stand the CLIMATEASY 12 on a firm flat level surface Connect the exhaust hose as follows expand a small section of the end and screw into the indoor adapter then slide the indoor adapter into the slot at the back of th...

Page 3: ...the hose as straight as possible avoid dips where the moisture from the exhaust air can condense and fill the tube with water Do not allow the hose to be crushed Correct Mounting Wrong bend of Exhaust Incorrect Bending of the Exhaust can cause malfunction The hose can be expanded up to 1 8 m long but the shorter it is the more efficiently the CLIMATEASY 12NG will operate Do not extend the hose or ...

Page 4: ...pose of the batteries in a fire as they may explode GENERAL SAFETY REQUIREMENTS Domestic wiring must be tested periodically by a qualified electrician at least once every 10 years or at every change of occupancy For office and retail premises and buildings such as village halls the wiring must be inspected at least once every 5 years It is recommended that all building be fitted with smoke alarms ...

Page 5: ...nce and any flammable materials Do not place on soft surfaces Do not cover Do not obstruct the air intakes and exhausts For indoor use only Not suitable for use in boats caravans or similar locations Do not use in bathrooms or in wet locations Do not place the mains lead beneath a carpet or rug Do not use the appliance in locations where paint petrol or other flammable liquids are used or stored A...

Page 6: ...Page 6 CONTROLS REMOTE DISPLAY ...

Page 7: ...re is above the selected temperature Then use the TEMP and TEMP buttons to select the desired room temperature When the temperature reaches the desired temperature the compressor will stop and the fan will continue to run Dehumidifying mode removes humidity but does not effect room temperature The fan operates at its lowest speed For best results do not use the exhaust tube but fit a permanent dra...

Page 8: ... fan speed control In all modes except dehumidifying mode The fan speed can be low medium or high The fan speed is indicated by the speed of the segments on the windmill symbol on the LED display TEMP and TEMP buttons Use the and buttons to select the desired room temperature The temperature can be set to any temperature from 16 C to 31 C Selecting a lower temperature whilst heating or a higher te...

Page 9: ... for three minutes and then disconnect from the mains supply Place a drainage pan underneath the drain outlet plug an the bottom of the unit at the back in the centre Withdraw the bung and allow the water to drain into the drainage pan Replace the bung and reconnect the unit to the mains supply The water should be disposed of down a drain To avoid the need to empty the water a permanent drain tube...

Page 10: ...sing the and buttons for the number of hours delay before switching on To cancel the timer press the POWER button SLEEP CONTROL FUNCTION 1 While in cooling mode press the SLEEP key to set the temperature It increases1 after an hour and at most increases 2 after 2 hours 2 Pressing the SLEEP key again cancels the setting 3 While in heating mode press the SLEEP key to set the temperature It decreases...

Page 11: ... washing up liquid to remove any dust or dirt from the case Do no use stronger detergents or solvents as these may damage the plastic Cleaning the filter The filter is located on the side panel of the appliance Unclip to remove then remove dust and dirt using a vacuum cleaner The filter should be cleaned every two weeks to maintain optimum performance Using a dry 1 25mm paint brush remove any dust...

Page 12: ...perature The unit is defrosting this will take a few minutes and afterwards it will resume operation Filter is blocked Cooling is poor on hot days Too much direct sunshine is heating the room Windows or doors are open allowing hot air into the room A lot of people in the room each person contributes about 75W of heating Electrical equipment in the room producing heat Heating is poor on cold days T...

Page 13: ...ight position DISPOSAL AND RECYCLING You must not dispose of this appliance with domestic household waste Most local authorities have specific collection system for appliances and disposal is free of charge to the end user When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for disposal This air conditioner contains R410a refrigerant gas At th...

Page 14: ...kmanship for a period of twelve months Should this unit be operated under conditions other than those recommended at voltages other than the voltage indicated on the unit or any attempts made to service or modify the unit then the warranty will be rendered void Please Note any attempt to extend the exhaust hose will invalidate the warranty The product you buy may sometimes differ slightly from ill...

Reviews: