BAKL40T12AF 

Edition: 20.03.2018 

Page: 7/10 

 

4.2. 

Flap for windshield/floor 

The flap for windshield respectively floor are controlled according to the symbolism.  

Arrow down: 

Flap for floor 

The whole air is lead to the floor  

Arrow down/up: 

Mid-position 

Air circulation is split up between floor and windshield. 

Arrow up 

Flap for windshield 

The whole air is lead to the windshield. 

Symbol windshield 

Defrost 

Water valve completely opened; air to windshield; max-
imal blower speed. 

The conversion is realized via characteristic curves which also facilitate intermediate positions.  

4.3. 

Desired value of front box temperature 

The blowout temperature of the front box can be set between 14 and 60º C. 

4.4. 

Blower speed 

The potentiometer serves for setting speed of the front box. The air velocity is increased by turning 
the potentiometer clockwise.  

4.5. 

Smog 

With the smog key you can stop supply of fresh air for the whole bus. If smog function is activated 
the key is illuminated. If this function is activated, the openings in the roof as well as the fresh air 
flaps are closed for a certain time prescribed by the manufacturer. 

4.6. 

Heater passenger’s compartment 

The driver doesn’t have the possibility to intervene in the fully automatic control of the passengers 
compartment. This control is merely turned off during routes without passengers (e.g. transportation 
of bus). If automatic function is activated the key is illuminated. 

4.7. 

Additional heater 

Normally the additional heater is turned on manually. If additional heater is activated, the key is illu-
minated. 

4.8. 

Reheat 

With the key Dry / Reheat the air conditioning unit is put into operation. The air is dried by cooling 
down and re-heating.  

4.9. 

Driver’s seat air conditioning 

This function activates the refrigerant magnetic valve respectively the compressor magnetic clutch. 
Key is illuminated if a/c system is activated.  

4.10.  General 

Roof ventilator: Roof ventilators are activated from a certain minimum speed of the roof evaporator 
blowers. In circulated air operation the roof ventilators are switched off. 

Summary of Contents for KL40T/24V

Page 1: ...ermany 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instruction for KONVEKTA Air Conditioning unit KL40T KL45T KL46T KL46S with Wabco ATC CAN control Versions 24 Volt DC Fresh Air Heating ID BBA KL40T12AF Version A06 ...

Page 2: ...oor 7 4 3 Desired value of front box temperature 7 4 4 Blower speed 7 4 5 Smog 7 4 6 Heater passenger s compartment 7 4 7 Additional heater 7 4 8 Reheat 7 4 9 Driver s seat air conditioning 7 4 10 General 7 5 Maintenance Service 8 5 1 Oil change Compressor type KVX 8 5 2 Return air grid 8 5 3 Condenser coil 8 5 4 Troubleshooting 9 6 Warranty Conditions 9 7 Waste disposal in accordance with legal p...

Page 3: ...dents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any warranty claims due to improper han dling inadequate maintenance applications that do not correspond with the determined use utiliza tion of non admitted fuels or the non observance of safety provis...

Page 4: ...s according to the copyright remain expressly reserved Manufacturer KONVEKTA AG P O Box 2280 D 34607 Schwalmstadt 1 Technical data air conditioning unit Type KL40T KL45T KL46T S Refrigerant R134a GWP 1 430 quantity with front box kgs approx 2 5 3 3 Operating voltage Volt DC 24 Current consumption stageless at 26V Ampere 53 Cooling capacity with KVX40 390 KVX40 560 KVX40 655K KVX30 oderTM31 TM65 Wa...

Page 5: ...o the observance of the Oper ating instruction and the proof of regular inspections as well 3 General information a c unit Attention in case of roof top a c units Never switch on the a c unit during car wash The a c unit is operational with running engine only At cooling operation the humidity inside the vehicle is decreased which avoids steamed up win dows The a c unit works most effectively with...

Page 6: ...onditioning unit when the traffic situation allows it Make sure you can clearly recognize and read all operation and display elements at any time Protect all displays against irritating sun glare and any other optical disturbances Please note that the control panel keys have not been designed for heavy stressing Excessive or fast pressing of the keys for adjusting the set temperature does not ac c...

Page 7: ...tion is activated the key is illuminated If this function is activated the openings in the roof as well as the fresh air flaps are closed for a certain time prescribed by the manufacturer 4 6 Heater passenger s compartment The driver doesn t have the possibility to intervene in the fully automatic control of the passengers compartment This control is merely turned off during routes without passeng...

Page 8: ...any maintenance works at your air conditioning unit carefully read the KONVKETA safety provisions TD00052A in order to avoid any dangers and accidents On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location Source of supply KONVEKTA AG P O Box 2280 D 34607 Schwalmstadt 5 1 Oil change Compressor type KVX Make f...

Page 9: ... necessary magnetic clutch check connections at magnetic clutch compressor does not compress check high and low pressure replace compressor if necessary excess pressure pressure too high check axial fans check fuses at switchboard clean condenser coil with compressed air excess pressure caused by high out side temperature run unit until pressure has stabilized 1 leakage in a c unit lack of refrige...

Page 10: ...ohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and gaseous substances e g mineral and tar oils cooling oils halogen containing organic...

Reviews: