NSC2U Server—Optional Component Installations
Kontron IP Network Server NSC2U
Product Guide, rev. 1.4
December 2009
94
3. Lift the battery assembly out of the case and insert the battery cable through the
opening in the bottom of the case. (
4. Attach the battery cable to the connector on the back of the battery assembly.
(“A”)
5. Put the battery assembly back into the case and close and latch the case lid. (“C”)
6. Place the IBBU on the bracket on the side wall of the chassis. (
, “A”)
7. Slide the IBBU away from the front panel to lock it into place. The plastic tab on
the IBBU case goes into the slot in the chassis (See the red arrow in
).
(“B”)
8. Connect the cable from the IBBU to the connector on the SFP board. (“C”)
9. Re-install the front panel bezel. For instructions, see
Section 3.2.4, “Installing the
10. If this is the last task you are performing, replace the processor air duct and the
top cover of the chassis. Reconnect all the external devices and plug in the power
cord(s).
For information about mounting the server in a rack, see
the Server into a Rack” on page 48