MOPSlcdGX1 Product Manual
Keyboard and Front-Panel Interface
Kontron Embedded Modules
Revision 1.3
20
10.3.6 VBAT (System Battery Connection)
•
This pin connects a system battery to all modules.
•
The battery voltage has to be higher than 2.85V and lower than 3.15V. Kontron
Embedded Modules recommends a 3V battery (for example, CR2032).
Note:
There is no battery needed to hold CMOS-setup data. Your configuration
information is saved in an onboard Ferroelectric Random-Access Memory (FRAM.)
However, you need a battery to run the CMOS date and time when power
consumption is off.
10.3.7 POWERGOOD (Reset Input 2)
•
Input on CPU modules
•
Open collector output on all other modules
•
When POWERGOOD goes high, it starts the reset generator on the CPU module
to pull the onboard reset line high after a valid reset period. You also can use this
pin as a low active hardware reset for modules.
10.4 Adapter Cable Pinout
(KLCK)
6
5
(DIN41524) FEMALE
6 PIN MINI-DIN FEMALE
(PS/2 STYLE)
(+5V Vcc)
(+5V Vcc)
(POWERGOOD)
(/KLOCK)
(RESIN)
(VBAT)
(Speaker)
(GND)
(KDATA)
3
5
2
1
4
3
5 PIN DIN 180°
1
2
4
(KLCK)
(GND)
(KDATA)