3.7.
Power Supply
In order to ensure safe operation of the board, the input power supply must monitor the supply voltage and shut
down if the supply is out of range – refer to the actual power supply specification. Please note, in order to keep the
power consumption to a minimal level, boards do not implement a guaranteed minimum load. In some cases, this can
lead to compatibility problems with power supplies that require a minimum load to stay in regulation. The mITX-SSH-
S board must be powered through the 2-pin Phoenix connector to a DC 12 V power source.
Hot Plugging power supply is not supported. Hot plugging might damage the board.
The requirements to the voltages of power source are as follows:
Table 5: Supply Voltages
Supply
Min.
Max.
Note
+12 V
11.4 V
12.6 V
±5% tolerance