Sub-Screen
Function
Second level Sub-Screen / Description
LVDS
Configurati
on
LVDS Flat Panel Display
Support [Disabled]
When set to Enabled:
Panel Type [Standard]
Resolution [1024 x 768]
Panel Color Depth [24-Bit VESA]
Panel Voltage [3.3V]
Channel [Dual]
Bus Swapping [Normal]
Clock Frequency Center Spread [Disabled]
Differential Output Swing Level [300 mV]
Backlight [Enable]
Backlight Signal Inversion [Disable]
Backlight PWM Frequency [200 Hz]
Brightness Level [80%]
Hardware
Monitor
Hardware Monitoring:
CPU DTS Temperature (CPU MSR)
PCB Temperature (TD1)
NCT7802Y Temperature (LTD)
LM75B Temperature (I2C0)
NCT7802Y Voltage (VCC)
RTC Voltage (VCORE)
DDR Voltage (VSENS2)
Input Voltage (VSENS3)
CPU Fan:
CPU Fan Pulse
CPU Fan Control Mode [SMART FAN IV]
Fan Trip Point
Trip Point Speed
CPLD
Configurati
on
Serial Port 0 [Enabled]
When set to Enabled:
Base Address [3E8]
IRQ [10]
GPIO IRQ [Disabled]
I2C IRQ [Disabled]
Watchdog
Auto-reload [Disabled]
Global Lock [Disabled]
Stage 1 mode [Disabled]
Thermal
Automatic Thermal
Reporting [Disabled]
When set to Disabled:
Critical Trip Point [125 C]
Passive Trip Point [95 C]
Passive TC1 value 1
Passive TC2 value 5
Passive TSP value 10
System
Component
OS Reset Select [Cold Reset]
Spread Spectrum Clocking Configuration
DDR SSC [Enable]
When set to Enable:
DDR SSC Selection Table [-0.5%]