www.kontron.com
17
MPC20/20L/21/21C MPC20WOL/21WOL
/ Specifications
Operating Temperature
Specifications
Without Hard Drive
-25°C to +70°C
With Standard Hard Drive
0°C to +50°C
With Extended Temperature Hard Drive
-25°C to +70°C
Operating Environment
Specifications
Relative Humidity
5-90% non-condensing
IEC68-2-30 at -+5 to +50°C operating
Vibration, operating
IEC68-2-6 10-50Hz, 0.075mm and 55-500Hz, 1.0G
Vibration, non-operating
IEC68-2-6 10-50Hz, 0.15mm and 55-500Hz, 2.0G
Shock, operating
IEC68-2-27 10G, 11ms ½ sine
Shock, non-operating
IEC68-2-27 50G, 11ms, ½ sine
Altitude
IEC68-2-13 4571meter operating
Security
e1
Not planned
UL
Not planned
ETL 301
Not planned
SEV
Safety
AR385-16
EMI / EMC Tests
Specifications
EMC Emission EN61000-6-2:2001
Conducted disturbance
EN55022 Class B
Radiated disturbance
EN55022 Class B
EMC Immunity EN61000-6-2
Electro-Static Discharge (ESD)
EN61000-4-2
Voltage = 4kV contact / 8kV air
Criteria A
Radiated RF Field
EN61000-4-3
Level = 10V/m
Criteria A
Electrical Fast Transients (burst)
EN61000-4-4
Grade 2: DC-Power lines = 1000V (5/50ns)
Grade 2: AC-Power lines = 2000V (5/50ns)
Grade 2: Signal lines = 500V (5/50ns)
Criteria B
Surge
EN61000-4-5
Grade 2: DC-Power lines = 1kV, (1.2/50us)
Grade 2: AC-Power lines = 2kV, (1.2/50us)
Criteria B
Conducted Disturbances
EN61000-4-6
Voltage = 10V coupled by case
Criteria A
Note:
All information is subject to change without notice.
Summary of Contents for Microspace Series
Page 1: ...If it s embedded it s Kontron MPC20 20L 21 21C MPC20WOL 21WOL Document Revision 101...
Page 2: ......
Page 41: ...www kontron com 39 MPC20 20L 21 21C MPC20WOL 21WOL Dimensions and Diagrams MPC21 Version 1 0...
Page 46: ...www kontron com 44 MPC20 20L 21 21C MPC20WOL 21WOL Dimensions and Diagrams Drilling Plan...
Page 59: ...www kontron com 57 MPC20 20L 21 21C MPC20WOL 21WOL Boot from LAN PXE WOL Wake On LAN...