LAN Support
•
1x 10/100/1000Mbits/s LAN (ETHER1):
Intel® Clarksville WGI218-LM Gigabit PHY w. AMT 9.0 (Q87 only)
Intel® Clarksville WGI218-V Gigabit PHY (H81 only)
•
1x 10/100/1000Mbits/s LAN (ETHER2) Intel®
Pearsonville I211AT
•
PXE Netboot supported.
•
Wake On LAN (WOL) supported
I/O Control
Via ITE IT8516E Embedded Controller via LPC Bus interface
Expansion
Capabilities
•
1x PCIe x16 (Gen 2.0), 1x mPCIe (w. USB2.0) (KTH81/mITX)
•
1x PCIe x16 (Gen 2.0 & 3.0), 1x mPCIe (w. USB2.0) (KTQ87/mITX)
•
1x PCIe x16 (Gen 2.0), 1x PCIe x2 (x16 slot), 1x PCIe x1 (KTH81/Flex)
•
1x PCIe x16 (Gen 2.0 & 3.0), 1x PCIe x4 (x16 slot), 1x PCIe x1 (KTQ87/Flex)
•
PCI (Flex only)
•
SMBus, compatible with ACCES BUS and I2C BUS, (via Feature connector)
•
SPI bus routed to SPI connector (BIOS Recovery module interface)
•
DDC/AUX Bus routed to DP connector (Auto detect to DDC when using passive DP to
HDMI or DVI adapters)
•
18 x GPIOs (General Purpose I/Os), (via Feature connector)
•
DAC, ADC, PWM and TIMER (Multiplexed), (via Feature connector)
•
WAKE UP / Interrupt Inputs (Multiplexed), (via Feature connector)
•
3 Wire Bus for GPIO Expansion (up to 152 GPIOs), (via Feature connector)
•
8 bit Timer output, (via Feature connector)
Hardware
Monitor
Subsystem
•
Smart Fan control system, support Thermal® and Speed® cruise for two on-board
Fan connectors: CPU Fan (on-board) and System Fan (on-board)
•
Thermal inputs: CPU Die temperature (pre/- 3ºC), System temperature
(pre/- 3ºC)
•
Intrusion (Case Open) detect input, (via Feature connector)
•
Sleep S5# Indication, (via Feature connector)
•
System Powergood Signal, (via Feature connector)
Power
Supply Unit
ATX/BTX (w. ATX+12V) PSU, 24-pin and 4-pin
Battery
Exchangeable 3.0V Lithium battery for on-board Real Time Clock and CMOS RAM.
Manufacturer Panasonic / Part-number CR-2032L/BN, CR2032N/BN or CR-2032L/BE.
Approximate 6.2 years retention.
Current draw is less than 4.2µA when PSU is disconnected and 0 µA in S0 – S5.
CAUTION: Danger of explosion if the battery is incorrectly replaced. Replace only
with the same or equivalent type recommended by the manufacturer. Dispose of