7. Installation Instructions
KBox A-201/A-202 – User’s Guide (Version 1.2)
30
www.kontron.com
7.1.
System Mounting
In order to adapt the KBox A-201/A-202 for mounting Kontron offers different mounting solution such as:
KBox A-201/A-202 configuration with vertical mounting plate for installation into a control cabinet or to a wall
KBox A-201/A-202 for DIN Rail mounting into a control cabinet
KBox A-201/A-202 for desktop operation without mounting
Depending on the ordered KBox A-201/A-202 configuration, your system is supplied with the corresponding mounting
plate or DIN Rail clip.
The key holes of the vertical mounting plate (Fig. 12, pos. 2) allow you to mount the KBox A-201/A-202 in vertical
position.
Prepare the mounting surface with four screws and if necessary anchors corresponding to the mounting surface type
(fire-resistant material). Please refer to the information for mounting in the section 10.1.2, “Mechanical Specifications of
the KBox A-201/A-202 with Vertical Mounting Plate” or refer to the drawings for KBox A-201/A-202 on our web site. The
drawings can be downloaded from our web site
by selecting the product name.
For a sufficient air circulation around the device, we recommend not to mount or operate any other
devices within the “Keep Out Area” around the KBox A-201/A-202; refer to the red marked area in
Fig. 15 and Fig. 16.
Fig. 15: Keep out area for mounting around KBox A-201/A-202 (side view with optional antenna)
GESPERRTER BEREICH
(Anschlüsse)
99.5
130
KEEP OUT AREA
(for cable connections)