3 Specifications
Kontron User's Guide ETX®-LX2
15
3.4.4
Supply Current (preliminary)
Power-consumption tests were executed under DOS and WindowsXP with 512MB of RAM.
DOS:
CPU Clock
500MHz
Mode
Prompt
Standby
Suspend
Power
Consumption
1.5 A
7,4 W
1,3 A
6,45 W
1,3 A
6,45 W
Windows XP:
CPU Clock
500MHz
Mode
Full Load
Idle
Standby S1
Standby S3
Power
Consumption
1.55 A
7,8 W
1,3 A
6,50 W
1,00 A
5,00 W
0,35 W
3.4.5
CMOS Battery Power Consumption
RTC
Voltage
Current
Winbond W83627HF
2.5V
1.6 µA
3.0V
2.7 µA
CMOS battery power consumption was measured with an ETX®-LX module on a standard Kontron ETX®
evaluation board. The system was turned off and the battery was removed from the evaluation board.
The 2.5 V or 3.0 V of power was supplied from a DC power supply. Do not use these values to calculate the
CMOS battery lifetime.