background image

www.kontron.com

CP3923 User Guide

61

The sensor number is the number which identifies the sensor e.g. when using the IPMI command “Get Sensor Reading”.

Table 4-6:

Sensor List

Sensor Number / ID 

string

Sensor Type (CODE)

Event Type Code / Event Offsets

NA / CP3923

NA (Management Controller Locator 

Record)

NA

1 / IPMI Info-1

C0h (OEM Kontron IPMI Firmware Info) Event Type: A0h (Discrete)

2 / IPMI Info-2

C0h (OEM Kontron IPMI Firmware Info) Event Type: A0h (Discrete)

3 / Storage Err

28h (Management Subsystem Health)

Event Type: 6Fh (Sensor Specific)

Refer to IPMI v1.5

4 / PM Reboot

24h (Platform Alert)

Event Type 03h (Generic)

Offset 0: Reset Asserted

5 / SEL State

10h (Event Logging Disabled)

Event Type: 6Fh (Sensor Specific)

Refer to IPMI v1.5

Offset 2: Log Area Reset/Cleared

Offset 4: SEL full

Offset 5: SEL almost full (75%)

6 / IPMI Wdt

23h (Watchdog 2)

Event Type: 6Fh (Sensor Specific)

Refer to IPMI v1.5 

7 / Board Reset

CFh (Kontron OEM)

Event Type: 03h (Digital Discrete)

Offset 1:

   Event data 2: reset type

      01h cold reset

   Event data 3: reset source

      00h IPMI watchdog

      01h IPMI command

      04h reset button  

      05h Power Up

      07h PPC watchdog

      08h SW initiated  

      FFh unknown

8 / HandleSwitch

24h (Platform Alert)

Event Type: 6Fh

Offset 0: assertion Handle state opened

9 / Health Error

24h (Platform Alert)

Event Type: 03h (Digital Discrete)

Offset 0: System is unhealthy

10 / Temp-PCB1

01h (Temperature)

Event Type: 01h (Threshold)

11 / Temp-PHY1

01h (Temperature)

Event Type: 01h (Threshold)

12 / Temp-PHY2

01h (Temperature)

Event Type: 01h (Threshold)

13 / Vcc5.0vCPCI

02h (Voltage)

Event Type: 01h (Threshold)

14 / Icc5.0vCPCI

03h (Current)

Event Type: 01h (Threshold)

15 / Vcc3.3vCPCI

02h (Voltage)

Event Type: 01h (Threshold)

16 / Icc3.3vCPCI

03h (Current)

Event Type: 01h (Threshold)

17 / Vcc3.3vCPLD

02h (Voltage)

Event Type: 01h (Threshold)

18 / Vcc3.3vSUS

02h (Voltage)

Event Type: 01h (Threshold)

19 / Vcc3.3v

02h (Voltage)

Event Type: 01h (Threshold)

20 / Vcc2.5v

02h (Voltage)

Event Type: 01h (Threshold)

21 / Vcc1.8v

02h (Voltage)

Event Type: 01h (Threshold)

22 / Vcc1.25v

02h (Voltage)

Event Type: 01h (Threshold)

23 / Vcc1.2v

02h (Voltage)

Event Type: 01h (Threshold)

Summary of Contents for CP3923 Series

Page 1: ...www kontron com CP3923 Document Revision 1 2 Date February 2016 User Guide...

Page 2: ...cked and is believed to be accurate however no responsibility is assumed for inaccuracies Kontron and the Kontron logo and all other trademarks or registered trademarks are the property of their respe...

Page 3: ...ew 12 1 1 1 CP3923 Features 12 1 1 2 General compliances 13 1 1 3 Hot Swap Capability 13 1 2 Optional Accessories 14 1 2 1 Rear IO Module 14 1 2 2 Serial Adapter Cable 14 1 3 Technical Specification 1...

Page 4: ...29 3 5 2 Uplink Ethernet Ports CP3923 8M and CP3923 4M 29 3 5 3 Serial Port not on CP3923 RC 30 3 5 4 Front Panel LEDs not on CP3923 RC 30 3 5 5 Front Panel Switches not on CP3923 RC 31 3 5 6 Backplan...

Page 5: ...Firmware 50 4 4 1 Supported IPMI Commands 51 4 4 2 Board Sensors 60 4 4 3 Board FRU Information 63 4 5 Firmware Administration 64 4 5 1 Updating Firmware 65 4 5 2 Updating IPMI 66 5 Thermal Considera...

Page 6: ...33 Table 3 12 Serial Port RJ45 Pin Assignment 35 Table 3 13 Ethernet Management RJ45 Connector Pin Assignment 35 Table 3 14 RIO Port Assignment 36 Table 3 15 MDI X RJ45 Pin Assignment 36 Table 4 1 POS...

Page 7: ...3 1 Functional Block Diagram CP3923 25 Figure 3 2 Front Panel of the CP3923 4M 34 Figure 3 3 Front Panel of the CP3923 8M 34 Figure 3 4 Front Panel of the CP3923 8C 34 Figure 3 5 Front Panel of the CP...

Page 8: ...ed to satisfy environmental protection requirements where possible Many of the components used structural parts printed circuit boards connectors batteries etc are capable of being recycled Final disp...

Page 9: ...bol indicates that the product described in this manual is in compliance with all applied CE standards Please refer also to the section Regulatory compli ance Statements in this manual WARNING All ope...

Page 10: ...o the device which are not explicitly approved by Kontron AG and described in this manual or received from Kontron s Technical Support as a special handling instruction will void your warranty This de...

Page 11: ...nal cost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron and the remaining part of the original...

Page 12: ...composed of the following building blocks Ethernet Infrastructure Unit Computer and Memory IPMI Power Supply 1 1 1 1 Ethernet Infrastructure Broadcom StrataXGS III Ethernet Switch Architecture BCM562...

Page 13: ...tion to Unit Computer via RS232 at J2 backplane connector 1 1 2 General compliances The Board is compatible to the following standards PICMG 2 0 R3 0 CompactPCI Specification PICMG 2 1 R2 0 CompactPCI...

Page 14: ...chips and ensuring stiffness of the complete PCB assembly These boards have standard CompactPCI front panels and handles The CP3923 RC cooling concept consists of a cooling frame with wedge locks whic...

Page 15: ...ormation on temperature see chapter Thermal Considerations on page 67 1 3 5 Humidity The board is designed to meet Bellcore GR63 Section 4 1 resp VITA 47 RC version Operating 93 non condensing at 40 C...

Page 16: ...requirement as specified in Telcordia GR 63 CORE UL 94V 0 1 with Oxygen index of 28 or greater material 1 3 11 Electromagnetic Compatibility The board is designed to meet or exceed class B limit of th...

Page 17: ...tion of speeds and operational mode on all external copper GE in terfaces as well as on all base fabric interfaces Layer 2 multicast services using GARP GMRP IEEE 802 1p VLAN support including VLAN ta...

Page 18: ...Persistent storage of configuration across restarts Support for retrieving and installing multiple configurations Support for startup configurations based on the cPCI system slot address Supported MIB...

Page 19: ...m temperature ESD Equipment This CompactPCI board contains electrostatically sensitive devices Please observe the necessary precautions to avoid damage to your board Discharge your clothing before tou...

Page 20: ...ding Carefully insert the board into the slot designated by the application requirements for the board until it makes contact with the backplane connectors Using the ejector handle engage the board wi...

Page 21: ...ard from the backplane pull the board out of the slot 11 Dispose of the board as required 2 4 Software Installation The CP3923 comes as a pre installed system with all necessary OS filesystem drivers...

Page 22: ...Serviceport The Gigabit Ethernet serviceport on the CP3923 RIO module has no IP address set by default it is necessary to assign an IP address statically or enable dhcp on the serviceport Because the...

Page 23: ...ocedure for assigning an IP address to the network port is described in the following User input is printed in bold letters 17 Connect to serial port on the front plate using the Kontron DB9 adapter c...

Page 24: ...aved Ethernet Fabric To access the CLI via the Gigabit Ethernet in band networkport open a telnet connection to the configured IP address port 23 It might make sense to separate the management network...

Page 25: ...et Hardware Monitor L E D B u s Octal PHY PCI 32 bit 66 MHZ Dual Magnetics Dual Magnetics Dual Magnetics Dual Magnetics RTC EEPROM I2C0 1GB NAND FLASH Single 10 100 1000 Base T PHY Octal PHY Fabric Sw...

Page 26: ...nagement application It is a PowerPC 405EX with following features 600MHz core frequency PCIe management connection to Ethernet Switch GbE connections to front management port and Ethernet Switch Tabl...

Page 27: ...SRAM It provides several I C interfaces for access to sensors and IPMB busses Board voltage current and temperature monitoring are accomplished through internal and external sensors The following sec...

Page 28: ...ole interface Two levels of HW write protection are supported standard and enhanced The protection level is set by a backplane signal EWP It is located on connector J2 pin A19 If left open the signal...

Page 29: ...rnet switch The following figure provides pinout information on the Gigabit Ethernet connectors Table 3 5 MDI X RJ45 Pin Assignment 3 5 2 Uplink Ethernet Ports CP3923 8M and CP3923 4M The eight four E...

Page 30: ...n with a terminal with a standard DB9 serial port 3 5 4 Front Panel LEDs not on CP3923 RC The front panel provides 12 or 16 LEDS depending on variant for status indication for the standard fabric inte...

Page 31: ...nserting or impending extraction of the board A reset switch is provided being activated with an adequate tool e g pencil When the switch is pressed the board per forms a power cycle to all payload de...

Page 32: ...ND V_IO_CPCI NC NC GND 19 V_3V3_CPCI NC NC GND NC GND 18 NC GND V_3V3_CPCI NC NC GND 17 V_3V3_CPCI IPMB0_SCL IPMB0_SDA GND NC GND 16 NC GND V_IO_CPCI NC NC GND 15 V_3V3_CPCI NC NC CPCI_BD_SEL NC GND 1...

Page 33: ...FL_DB8 FL_DB8 GND FL_DD8 FL_DD8 GND 14 FL_DA7 FL_DA7 GND FL_DC7 FL_DC7 GND 13 FL_DB7 FL_DB7 GND FL_DD7 FL_DD7 GND 12 FL_DA6 FL_DA6 GND FL_DC6 FL_DC6 GND 11 FL_DB6 FL_DB6 GND FL_DD6 FL_DD6 GND 10 FL_DA...

Page 34: ...www kontron com CP3923 User Guide 34 3 5 7 Front Panel Drawings Figure 3 2 Front Panel of the CP3923 4M Figure 3 3 Front Panel of the CP3923 8M Figure 3 4 Front Panel of the CP3923 8C...

Page 35: ...232 signals from connector J4 are routed to a RJ45 connector in the faceplate The connector has the following pin assignment 3 6 2 Ethernet Management Interface The Unit Computer s Ethernet Interface...

Page 36: ...signment Table 3 14 RIO Port Assignment CLI Interface Speed Settings 0 1 Backplane Link 1 10 100 1000 Mbps 0 2 Backplane Link 2 10 100 1000 Mbps 0 3 Backplane Link 3 10 100 1000 Mbps 0 4 Backplane Lin...

Page 37: ...www kontron com CP3923 User Guide 37 3 6 4 Front Panel Elements Figure 3 5 Front Panel of the CP RIO3 923 8C...

Page 38: ...CLI Reference Manual 4 1 Supported RFCs The Software supports the following standards and RFCs 4 1 1 Management RFC 826 ARP RFC 854 Telnet RFC 855 Telnet Option RFC 1155 SMI v1 RFC 1157 SNMP RFC 1212...

Page 39: ...TP over TLS SSH 1 5 and 2 0 RFC 4253 SSH transport layer protocol RFC 4252 SSH authentication protocol RFC 4254 SSH connection protocol RFC 4251 SSH protocol architecture RFC 4716 SECSH public key fil...

Page 40: ...1 2 802 1Q 2003 RFC 4541 IGMP snooping and MLD snooping Broadcast storm recovery Double VLAN vMAN tagging DHCP Snooping Dynamic ARP inspection Independent VLAN Learning IVL support Jumbo Ethernet fram...

Page 41: ...idelines 4 1 3 Routing Weighted Static Routes RFC 819 Domain Naming Convention for Internet User Applications RFC 826 Ethernet ARP RFC 894 Transmission of IP datagrams over Ethernet networks RFC 896 C...

Page 42: ...ny actions for inbound or outbound Layer 2 traffic classification based on Source MAC address Destination MAC address EtherType VLAN identifier value or range outer and or inner VLAN tag 802 1p user p...

Page 43: ...following MIBs 4 2 1 Enterprise MIB Support for all managed objects not contained in standards based MIBs 4 2 2 Switching Package MIBs RFC 1213 MIB II RFC 1493 Bridge MIB Definitions of Managed Objec...

Page 44: ...e OSPF Version 2 Protocol RFC 2787 VRRP MIB Definitions of Managed Objects for the Virtual Router Redundancy Protocol DVMRP STD MIB Distance Vector Multicast Routing Protocol MIB IANA RTPROTO MIB IANA...

Page 45: ...efinitions for the View based Access Control Model for SNMP 4 2 7 Kontron Private MIBs For the CP3923 Kontron provides several MIBs in addition to the Standard MIBs see Supported MIBs on page 43 that...

Page 46: ...ustomer specific information OEM serial number OEM hardware part number OEM software part number OEM software configuration kex_phy handling of PHY interfaces SFP XFP kex_ref basic Kontron Information...

Page 47: ...he following table shows the POST code values written into the CPLDs postcode register in case of a POST error Table 4 1 POST tests Test Description Serial Onboard Unit Computer serial controller loop...

Page 48: ...your bootcmd variable this can prevent you from entering interactive commands again forever Set this variable to 1 to disable autoboot default 3 for boot monitor 10 for boot write protected boot firm...

Page 49: ...ript variables However definition and execution of user defined script variables can be done postresult Auto Stores the POST result 0 no POST error occurred 1 a POST error occurred recover_flash Scrip...

Page 50: ...e and integrated RAM for data The field replaceable unit FRU inventory information is stored in the nonvolatile memory on an EEPROM con nected via a local I2C interface to the PM microcontroller It is...

Page 51: ...24h O Yes Get Watchdog Timer 27 7 App 25h O Yes BMC Device and Messaging Commands O Set BMC Global Enables 22 1 App 2Eh O No Get BMC Global Enables 22 2 App 2Fh O No Clear Message Flags 22 3 App 30h...

Page 52: ...7h O No Chassis Device Commands O Get Chassis Capabilities 28 1 Chassis 00h O Yes Get Chassis Status 28 2 Chassis 01h O Yes Chassis Control 28 3 Chassis 02h O Yes Chassis Reset 28 4 Chassis 03h O No C...

Page 53: ...sitory Allocation Info 33 10 Storage 21h O No Reserve SDR Repository 33 11 Storage 22h O No Get SDR 33 12 Storage 23h O No Add SDR 33 13 Storage 24h O No Partial Add SDR 33 14 Storage 25h O No Delete...

Page 54: ...4 5 Kontron OEM Commands Command LUN NetFn CMD OemApSetNvParam 3 3Eh 05h OemApFormatStorage 3 3Eh 09h OemApRefreshExternUpdatedSensor 3 3Eh 02h OemApSetManufacturingDate 3 3Eh 0dh OemApGetManufacturin...

Page 55: ...vision BCD encoded returned as 24h 6 IPMI Version returned as 51h 7 Additional Device Support 7 Chassis device returned as 1 6 Bridge returned as 0 5 IPMB Event Generator returned as 1 4 IPMB Event Re...

Page 56: ...2 reserved 1 1 set values 0 get values 0 is cold reset required flag 6 Operation Mode 7 5 reserved 4 IPMB Mode 1 redundant 0 non redundant 3 1 reserved 0 Controller mode 1 BMC mode 0 Satellite Mode 7...

Page 57: ...Code 0 K 0xBA Pass Code 1 o 0x90 Pass Code 2 n 0x91 Pass Code 3 t 0x8B 4 N Externally Updated Sensor Values Response data 1 Completion Code LUN NetFn CMD OemApSetManufacturingDate 3 OEM 3Eh 0dh Byte...

Page 58: ...s Code 0 K 0xBA Pass Code 1 o 0x90 Pass Code 2 n 0x91 Pass Code 3 t 0x8B Response data 1 Completion Code 2 4 Manufacturing Date LUN NetFn CMD OemApGet ReleaseInfo 3 OEM 30h 01h Byte Data Field Request...

Page 59: ...s Code 0 S 2 Pass Code 1 1 3 Pass Code 2 8 4 Pass Code 3 0 5 Pass Code 4 0 Response data 1 Completion Code 2 19 Firmware capabilities vector LUN NetFn CMD OemApSetFirmwareCapabilities 3 OEM 30h 04h By...

Page 60: ...value Module sensors that have been implemented are listed in the sensor list in Table 4 6 4 4 2 1 Sensor List The sensor name ID string has a name prefix which is Sxx in the lists below When reading...

Page 61: ...h Digital Discrete Offset 1 Event data 2 reset type 01h cold reset Event data 3 reset source 00h IPMI watchdog 01h IPMI command 04h reset button 05h Power Up 07h PPC watchdog 08h SW initiated FFh unkn...

Page 62: ...t 0 Diagnostic Started Offset 1 Diagnostic PASS Offset 2 Diagnostic FAIL Table 4 7 Temperature Sensor Thresholds C SENSOR Number ID string Lower criti cal Lower non critical Nominal Upper non critical...

Page 63: ...es which may differ depending on the used board typ FRU Board Info Area Manufacturing date time Board manufacturer Kontron Board Product Name CP3923 8M Board Serial Number 1234567890 Board Part Number...

Page 64: ...artitions mtd0 4 whereas the second bank is stored in partition mtd5 Partition mtd6 holds the bootloader boot firmware which is stored in one single write protected flash sec tor The partition scheme...

Page 65: ...ry from the redundant system in case that update fails due to power loss or similar errors The system update package cp3923 update release pkg contains an image of bootloader kernel root filesystem an...

Page 66: ...de with image1 are lost and shoud be saved by copying image1 to image 2 before 6 It is recommended to copy image 1 to image 2 to have a fully redundant system Ethernet Fabric copy image1 image2 Copyin...

Page 67: ...de any active means of temperature regulation The complete list of sensors and their alarm thresholds can be found in chapter Board Sensors on page 60 As long as the temperature values stay below thei...

Page 68: ...ame Using a frame with good conduction cooling capabilities can decrease the difference between reference and ambient temperature Table 5 2 Thermal Requirements Device Operation Mode Cooling Maximum T...

Page 69: ...t be exceeded Power supplies to be used with the CP3923 should be carefully tested to ensure compliance with these ratings 6 1 2 Backplane Backplanes to be used with the CP3923 must be adequately spec...

Page 70: ...be sufficient to allow for backplane input line resistance variations due to temperature changes etc 6 1 3 1 Start up Requirement Power supplies must comply with the following guidelines in order to...

Page 71: ...nce Maxi Ripple p p Remarks 5 V 5 0 VDC 5 3 50 mV Main Voltage 3 3 V 3 3 VDC 5 3 50 mV VI O PCI Voltage 3 3 VDC or 5 VDC 5 3 50 mV GND Ground not directly connected to potential earth PE WARNING All o...

Page 72: ...than the maximum currents given in Table 6 3 for each of the variants Note The power consumption values indicated in the tables below can vary depending on the ambient temperature or the system perfo...

Page 73: ...cific 17 Building Block 1 ABP 188 Southern West 4th Ring Road Beijing 100070 P R China Tel 86 10 63751188 Fax 86 10 83682438 info kontron cn CP3923 User Guide All data is for information purposes only...

Reviews: