CP3923 Initial Installation Procedures
The following procedures are applicable only for the initial installation of the CP3923 in a system. Procedures for standard
removal and hot swap operations are found in their respective chapters.
To perform an initial installation of the CP3923 in a system proceed as follows:
1. Ensure that the safety requirements indicated in chapter Safety Requirements are observed.
2. Ensure that the board is properly configured for operation in accordance with application requirements before in-
stalling. For information regarding the configuration of the CP3923 refer to the CLI Reference Manual.
3. To install the CP3923 perform the following:
• Ensure that no power is applied to the system before proceeding.
• Carefully insert the board into the slot designated by the application requirements for the board until it makes
contact with the backplane connectors.
• Using the ejector handle, engage the board with the backplane. When the ejector handle is locked, the board is
engaged.
• Fasten the front panel retaining screws.
• Only non-conduction-cooled versions: Connect all external interfacing cables to the board as required.
• Ensure that the board and all required interfacing cables are properly secured.
4. The CP3923 is now ready for operation.
WARNING
Failure to comply with the instruction below may cause damage to the board
or result in improper system operation.
WARNING
Care must be taken when applying the procedures below to ensure that nei-
ther the CP3923 nor other system boards are physically damaged by the
application of these procedures.
WARNING
DO NOT push the board into the backplane connectors. Use the ejector han-
dle to seat the board into the backplane connectors.