For Your Safety 

Your new Kontron product was developed and tested carefully to provide all features necessary to ensure its 
compliance with electrical safety requirements. It was also designed for a long fault-free life. However, the life 
expectancy of your product can be drastically reduced by improper treatment during unpacking and installation. 
Therefore, in the interest of your own safety and of the correct operation of your new Kontron product, you are 
requested to conform with the following guidelines. 

High Voltage Safety Instructions 

As a precaution and in case of danger, the power connector must be easily accessible. The power connector is the 
product’s main disconnect device. 

 

 

 

Warning 
All operations on this product must be carried out by sufficiently skilled personnel only.

 

 

 

 

 

Electric Shock!  
Before installing a non hot-swappable Kontron product into a system always ensure that 
your mains power is switched off. This also applies to the installation of piggybacks. Serious 
electrical shock hazards can exist during all installation, repair, and maintenance operations 
on this product. Therefore, always unplug the power cable and any other cables which 
provide external voltages before performing any work on this product. 
Earth ground connection to vehicle’s chassis or a central grounding point shall remain 
connected. The earth ground cable shall be the last cable to be disconnected or the first 
cable to be connected when performing installation or removal procedures on this product. 

 

Special Handling and Unpacking Instruction 

 

 

 

ESD Sensitive Device! 
Electronic boards and their components are sensitive to static electricity. Therefore, care 
must be taken during all handling operations and inspections of this product, in order to 
ensure product integrity at all times. 

 

Do not handle this product out of its protective enclosure while it is not used for operational purposes unless it is 
otherwise protected. 

Whenever possible, unpack or pack this product only at EOS/ESD safe work stations. Where a safe work station is not 
guaranteed, it is important for the user to be electrically discharged before touching the product with his/her hands or 
tools. This is most easily done by touching a metal part of your system housing. 

It is particularly important to observe standard anti-static precautions when changing piggybacks, ROM devices, jumper 
settings etc. If the product contains batteries for RTC or memory backup, ensure that the product is not placed on 
conductive surfaces, including anti-static plastics or sponges. They can cause short circuits and damage the batteries 
or conductive circuits on the product. 

Summary of Contents for CP347

Page 1: ...USER GUIDE CP347 Doc User Guide Rev 1 3 Doc ID 1060 5099...

Page 2: ...CP347 User Guide Rev 1 3 www kontron com 2 This page has been intentionally left blank...

Page 3: ...be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions whic...

Page 4: ...s contact information on the last page of this user guide or visit our website CONTACT US Customer Support Find Kontron contacts by visiting http www kontron com support Customer Service As a trusted...

Page 5: ...cribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensitive...

Page 6: ...efore performing any work on this product Earth ground connection to vehicle s chassis or a central grounding point shall remain connected The earth ground cable shall be the last cable to be disconne...

Page 7: ...ssary to store or ship the product then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instructio...

Page 8: ...l I O Connector 20 2 3 1 Front Panel Adapter Cable 37 Pin to 4x 9 Pin 21 2 3 2 JTAG Connector 21 2 3 3 CompactPCI Connector 21 2 3 4 3 Configuration 22 3 1 Hardware Configuration 22 Serial Mode Config...

Page 9: ...in D Sub Front Panel Connector Pin Assignment 21 Table 7 Serial Mode DIP Switch CP347 Configuration 22 Table 8 RS422 RS485 Termination Jumper Settings 22 Table 9 RS485 Transceiver Control RTS and DTS...

Page 10: ...eparate serial I O channeling it is possible to connect a front panel adapter to the 37 pin front panel connector This adapter terminates on the user side with four male 9 pin D Sub connectors one per...

Page 11: ...CP347 User Guide Rev 1 3 www kontron com 11 1 2 Board Diagrams Figure 1 CP347 Functional Block Diagram...

Page 12: ...S232 or RS 422 RS485 serial interfaces controlled and converted by a PCI to serial controller For the 37 pin D Sub connector s pin assignment see Chapter 2 3 1 Front Panel Serial I O Connector 1 2 1 1...

Page 13: ...n3 12 pin JTAG ISP connector 2 3 3 14 Con1 CompactPCI connector J1 in the CompactPCI specification 2 3 4 Item Configurable Components Description Chapter 2 R16 R17 R18 R19 R20 R21 R22 R23 8x 0 resisto...

Page 14: ...3 1 3 23 JP1 JP2 JP3 JP4 JP5 JP6 JP7 JP8 Bus termination solder jumpers Listed from top to bottom 3 1 2 Item Components Description 7 U7 CPLD 9 U11 Voltage translator 12 U3 U4 U8 U12 U16 U20 U22 U25 D...

Page 15: ...ftware Serial Data Rates Up to 115 2 kbps Programmable Data Formats Up to 64 byte transmit and receive FIFOs Automatic RTS CTS or DTR DSR flow control Automatic Xon Xoff software flow control Automati...

Page 16: ...rature Extended range 40 C to 85 C In a passive cooled system the maximum ambient temperature is 63 C Storage Temperature 55 C to 125 C Humidity 93 RH non condensing Operating Altitude Up to 2000 m Th...

Page 17: ...2 Electrostatic Discharge EN 61000 4 3 RF electromagnetic fields EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 4 6 Conducted interferences Safety EN 60950 1 UL CSA 60950 1 Electrical safety IT equipm...

Page 18: ...ates the serial channels from the CompactPCI interface The CP347 provides a universal CompactPCI interface and can work properly with 5 V and 3 3 V PCI V I O signaling 1 7 Related Publications Table 4...

Page 19: ...via the standard PCI interface provided directly on the Exar XR17D154 Logical control of the CP347 serial communication operation is accomplished via the Exar XR17D154 command and status registers tha...

Page 20: ...ront Panel Pin RS232 Direction RS232 RS485 Half Duplex RS422 Full Duplex Front Panel 37 Pin D Sub Connector 0 FE01 37 In DCD RxD FE02 36 In RXD FE03 35 Out TXD TRxD TxD FE04 34 Out DTR FE06 18 In DSR...

Page 21: ...Sub Front Panel Connector Pin Assignment D Sub Pin RS 232 Signal RS 422 Signal Full Duplex RS 485 Signal Half Duplex 1 DCD RxD NC 2 RxD NC NC 3 TxD TxD TRxD 4 DTR NC NC 5 GND GND GND 6 DSR RxD NC 7 R...

Page 22: ...ngs where switch setting are either On or Off and resistor setting are either Open or Set Table 7 Serial Mode DIP Switch CP347 Configuration Channel Channel 0 Channel 1 Channel 2 Channel 3 Switch Resi...

Page 23: ...s an assembled 0 resistor Table 9 RS485 Transceiver Control RTS and DTS Resistor Configuration Channel 0 Channel 1 Channel 2 Channel 3 R32 R33 R45 R44 R46 R47 R38 R37 RTS Signal Controls DE RE default...

Page 24: ...for the system master slot Consider the board s location within a system carefully Factors such as the number of CP347 boards their locations in a given system and the operating system in use may cau...

Page 25: ...eeding Do not push the board into the backplane connectors Use the ejector handles to seat the board into the backplane connectors 2 Insert the board into the designated slot carefully until it makes...

Page 26: ...able CP ADAP CP346 CP347 can be connected to the CP347 s 37 pin D Sub front panel connector The front panel adapter terminates on the user side with four male 9 pin D Sub connectors that include the s...

Page 27: ...ilable for the CP347 For more detailed driver installation information refer to the relevant CP347 driver documentation For more information contact Kontron Support Install all boards required for the...

Page 28: ...Controller Style KVM Keyboard Video Mouse MEI Management Engine Interface NCSI Network Communications Services Interface OSI Open System Interconnection PCI Peripheral Component Interface PCIe PCI Ex...

Page 29: ...rtfolio of secure hardware middleware and services for Internet of Things IoT and Industry 4 0 applications With its standard products and tailor made solutions based on highly reliable state of the a...