COMe-cHL6 / BIOS Operation
79
Watchdog
Feature
Options
Description
Auto-reload
Disabled
Enabled
Enable automatic reload of watchdog timers on timeout
Global Lock
Disabled
Enabled
If set to enabled, all Watchdog registers (except
WD_KICK) become read only until the board is reset
Stage 1 Mode
Disabled
Reset
NMI
SCI
Select Action for first Watchdog stage
- Assert WDT Signal
Enabled
Disabled
Enable/Disable assertion of WDT signal to baseboard on
stage timeout
- Stage 1 Timeout
1s
5s
10s
30s
1m
3m
10m
30m
Select Timeout value for first watchdog stage
Stage 2 Mode
Disabled
Reset
NMI
SCI
Select Action for first Watchdog stage
- Assert WDT Signal
Disabled
Enabled
Enable/Disable assertion of WDT signal to baseboard on
stage timeout
- Stage 2 Timeout
1s
5s
10s
30s
1m
3m
10m
30m
Select Timeout value for second watchdog stage
Summary of Contents for COMe-cHL6
Page 1: ...www kontron com COMe cHL6 Document Revision 2 0...
Page 2: ...This page has been intentionally left blank...
Page 28: ...COMe cHL6 Product Specification 28 3 11 Module Dimensions All dimensions in mm...
Page 67: ...67 COMe cHL6 BIOS Operation System Information...
Page 71: ...COMe cHL6 BIOS Operation 71 Platform Information...
Page 72: ...COMe cHL6 BIOS Operation 72 8 5 2 Advanced...
Page 73: ...COMe cHL6 BIOS Operation 73 Silicon Information...
Page 100: ...COMe cHL6 BIOS Operation 100 ME Configuration...
Page 101: ...COMe cHL6 BIOS Operation 101 Thermal Configuration...
Page 111: ...COMe cHL6 BIOS Operation 111 8 5 4 Boot...