6. Product Description 

 

CB 752 – User's Guide (Version 1.01) 

 

6.5.

 

Bottom Side 

At the bottom side are located: the type label, the inspection status label and if applicable, the license sticker. 

 

 

 

 

1

3

4

Fig. 19: Bottom side  

 

1

 

Knurled screws of the CF slot access 
cover 

2

 

Rubber feet of the desktop version 

3

 

Countersunk screws M3x6 DIN7991 A2 torx for 
mounting of the bottom section of the device 

4

 

Countersunk screws M3x6 DIN7991 A2 torx for 
mounting of the bottom section of the device 
and of the optional brackets (for wall or table 
mounting) 

 

 

 

 

 

 

 

www.kontron.com 

19 

Summary of Contents for CB 752

Page 1: ...CB 752 User s Guide Version 1 01 0 0096 4743 If it s embedded it s Kontron...

Page 2: ...This page is intentionally left blank www kontron com...

Page 3: ...1 2 Controls and Indicators 12 6 1 3 External Interfaces of the SBC Board at the Front Side 13 6 1 4 Optional Interfaces on the Front Side 14 6 2 Rear Side 16 6 2 1 Audio LINE IN LINE OUT and MIC IN 1...

Page 4: ...figured as RS485 4 wire mode full duplex bus master 38 12 1 5 Serial Port COM2 RS422 RS485 configured as RS485 2 wire mode half duplex 39 12 1 6 VGA Port 39 12 1 7 CAN Bus Connector 40 12 1 8 USB Port...

Page 5: ...g 26 Right mounting bracket optional 27 Fig 27 Rear side detail without CF access cover 28 Fig 28 Dimensions in the front view desktop 31 Fig 29 Dimensions in the side view desktop 31 Fig 30 Dimension...

Page 6: ...r this reason Kontron Embedded Computers expressly informs the user that this manual only contains a general description of technical processes and instructions which may not be applicable in every in...

Page 7: ...nding warning notices are not observed This symbol indicates that the product or parts thereof may be damaged if the corresponding warning notices are not observed This symbol indicates general inform...

Page 8: ...ility Obligation Kontron Embedded Computers shall be exempted from the statutory accident liability obligation if the user fails to observe the included document General Safety Instructions for IT Equ...

Page 9: ...eel straps or air ionizes to give added protection 3 Always handle electrostatically sensitive components by their edge or by their casing 4 Avoid contact with pins leads or circuitry 5 Turn off power...

Page 10: ...l interference in which case the user will be required to correct the interference at his own expense English This Class A digital apparatus complies with the Canadian ICES 003 French Cet appareil num...

Page 11: ...RS232 internally installed CAN bus module internally installed A customer specific configuration of the CB 752 platform with the following optional add on modules can only be factory provided LVDS to...

Page 12: ...d with an internal 2 5 HDD SATA or SSD and or a CompactFlash card type I see chapter 6 3 Storage Media The CB 752 is a fanless system with a compact aluminum chassis with cooling fins The rated voltag...

Page 13: ...ical Specifications 6 1 Front View Fig 9 CB 752 Front view 6 3 4 7 8 9 1 2 10 10 5 1 DC IN power connector 2 External connectors of the installed SBC 3 Air openings at the front side 4 Controls and in...

Page 14: ...BC Switching the system off using the power button does not disconnect the device from the mains The unit is only completely disconnected from the mains when the power cord is disconnected either from...

Page 15: ...5 VGA port 6 1 3 1 LAN Ports These ports Fig 11 pos 1 and pos 2 consist of RJ45 connectors with integrated LEDs and support a transfer rate of 10 100 1000Mbps Left LED Color Link Status Right LED Col...

Page 16: ...2 configurable as RS422 RS485 This serial port Fig 9 Pos 6 can be custom configured as RS422 or RS485 The customer specific configuration of this serial port of the CB 752 platform as RS422 and or RS4...

Page 17: ...CAN bus interface you need to specify the requirements configuration of this port See following settings options SJA Base Address SJA Interrupt Address Range IRQ 0x340 to 0x35F 0x320 to 0x33F 15 NVRAM...

Page 18: ...pos 5 loudspeakers headphones Line Out a recording playing device Line In and a microphone Mic In can be connected 6 2 2 USB Ports The CB 752 platform provides two USB2 0 ports on the rear side Fig 1...

Page 19: ...antenna connector Hinge for positioning the antenna 6 2 4 CF Slot Access Cover To gain access to the CF slot or to the CF card and to the lithium battery you have to loosen the two knurled screws Fig...

Page 20: ...for the cooling of the CB 752 platform never cover the cooling fins of the chassis Do not place any objects onto the device 4 2 1 3 Fig 16 Right side of the chassis Fig 17 Top side of the chassis Fig...

Page 21: ...cker 1 3 2 2 2 4 2 4 Fig 19 Bottom side 1 Knurled screws of the CF slot access cover 2 Rubber feet of the desktop version 3 Countersunk screws M3x6 DIN7991 A2 torx for mounting of the bottom section o...

Page 22: ...20 DC power cord 6 7 AC DC Adapter Option The external AC DC adapter is provided with an AC power cord AC DC Adapter Power status LED of the AC DC adapter DC out connector AC in connector Fig 21 AC DC...

Page 23: ...nected from the main power supply Please follow the safety instructions for components that are sensitive to electrostatic discharge ESD Failure to observe this warning notice may result in damage to...

Page 24: ...h the connectors facing forward into the CF slot Fig 15 5 Press the CompactFlash card carefully into the CF card slot as far as it will go 6 Insert the laces of the CF card access cover into the cente...

Page 25: ...witch on the DC main power supply via the disconnect device It must be ensured that the system can be powered ON and OFF via a readily accessible two pole disconnect device that shall be incorporated...

Page 26: ...t connector Fig 9 pos 1 of the CB 752 platform The DC input connector is located on the front side and is marked DC IN 2 Connect the AC power cord to the AC DC adapter 3 Connect the other end of the A...

Page 27: ...ur system is fully operational when you switch it on for the first time If you have ordered CB 752 without a pre installed operating system you will need to install the operating system and the approp...

Page 28: ...e device are free and not obstructed by objects Operate the device within the intended temperature range to prevent possible overheating see chapter 11 3 Environmental Specifications chapter 4 Safety...

Page 29: ...mounting brackets to the bottom side of the CB 752 platform Use the installed torx screws Fig 19 pos 4 To do so the rubber feet have to be removed first Depending on the surface on which the CB 752 p...

Page 30: ...for replacing inserting the lithium battery into from the battery holder Please follow the safety instructions for components that are sensitive to electrostatic discharge ESD Failure to observe this...

Page 31: ...gainst Overheating The system comes with a protective function against overheating The implemented protective function against overheating will turn off the system when the specified maximum environme...

Page 32: ...x USB 2 0 for system configuration without equipped optional serial port COM3 or 1x lower USB 2 0 port for system configuration equipped with the optional serial port COM3 Options 1x WiFi optional wit...

Page 33: ...ensions For a sufficient air circulation around the device we recommend not to place mount or operate any other devices within the restriction area marked with 40mm all around the cooling fins of the...

Page 34: ...11 Technical Data CB 752 User s Guide Version 1 01 Fig 30 Dimensions in the rear view desktop Fig 31 Dimensions in the bottom view desktop 32 www kontron com...

Page 35: ...erate any other devices within the restriction area marked with 40mm all around the cooling fins of the chassis see Fig 32 The restriction area marked with 100mm at the front and rear side of the plat...

Page 36: ...11 Technical Data CB 752 User s Guide Version 1 01 Fig 34 Dimensions in the top view wall or table mounting Fig 35 Dimensions in the rear view wall or table mounting 34 www kontron com...

Page 37: ...ystem configuration with non rotating storage media e g with CF Storage Transport Temp Relative Humidity 25 70 C 5 95 40 C not condensing 13 158 F 5 95 104 F not condensing Max Operation Altitude 3 04...

Page 38: ...8 EG EC marking Council Directive 93 68 EEC Electrical Safety Standards EUROPE Information technology equipment Safety Part 1 General requirements EN 60950 1 2006 U S A CANADA to meet UL60950 1 2006 E...

Page 39: ...Pin Signal Name 3 pin DC In connector male 1 0V input 2 NC 3 24 VDC input 12 1 2 Serial Port COM1 COM2 and COM3 RS232 Pin Signal Name 9 pin D SUB connector male 1 DCD Data Carrier Detect 2 RXD Receive...

Page 40: ...Transmit Data 4 RxD Receive Data 5 GND Signal Ground 6 RTS Request to Send 7 RTS Request to Send 8 CTS Clear to Send 9 CTS Clear to Send 12 1 4 Serial Port COM2 RS422 RS485 configured as RS485 4 wire...

Page 41: ...plex Pin Signal Name 9 pin D SUB connector female 1 Data 2 NC 3 Data 4 NC 5 GND Signal Ground 6 NC 7 NC 8 NC 9 NC 12 1 6 VGA Port Pin Signal Name 15 pin D SUB connector female 1 Analog red output 2 An...

Page 42: ...hapter 6 1 4 4 Optional CAN Bus interface Pin Signal Name 9 pin D SUB connector male 1 NC 2 CANL galvanically separated 3 CAN0V galvanically separated 4 NC 5 NC 6 NC 7 CANH galvanically separated 8 NC...

Page 43: ...MA No RMA Return of Material Authorization from our website www kontron com Support RMA Information contact our Customer Service department to obtain an RMA No Fax 49 8165 77 412 e Mail service kontro...