MAINTENANCE

9

STORAGE AND TRANSPORTATION

10

When transporting and storing the device, keep the device away from moisture.

If you are not going to use the ATS unit for a long time, be sure to turn it off and disconnect it from the 

mains supply. It is recommended to keep the device in a dry, well-ventilated area and not expose it to 

high humidity, corrosive hazardous gases and dust. Keep away from children and animals.

The device is energized, which is life threatening.

WARRANTY PROVISIONS

11

The warranty period is 1 year and starts from the date of purchase of the product. All faults caused by the 

manufacturer during the warranty period will be eliminated free of charge. The warranty becomes effective 

only if the warranty card and  tear-off coupons have been filled out correctly. The device is accepted for 

repair clean and full.

WARRANTY DOES NOT COVER:
-  Mechanical damage (cracks, paint peeling, etc.) and damage caused by the action of aggressive media, 

ingress of foreign objects into the product or air inlet screen, as well as damage resulting from improper 

storage (corrosion of metal parts);

-  Malfunctions  resulting  from  improper  operation,  unintended  use  of  the  product,  overloading  of  the 

product, as well as instability of the mains parameters. The product overload is indicated by melting or 

discoloration of parts due to the effect of high temperature, score marks on the cylinder or piston surfaces, 

destruction of connecting rod inserts or piston rings. In addition, the warranty obligations do not apply to 

the failure of the automatic voltage regulator of power generators due to improper operation;

-  Quick-wearing parts (V-belts, rubber seals, spark plugs, nozzles, clutch springs, pulleys, guide rollers, 

cables, manual starters, clamping chucks, removable batteries, filter and safety elements, oil, removable 

devices, fittings, etc.);

- Electric cables with mechanical and thermal damage;
- The product tampered with or repaired not by the authorized service center;
- Preventive maintenance (cleaning, washing, greasing, etc.), installation and setup of the product;
- Normal wear and tear of the product (remaining life);
- Malfunctions arising from the use of the product for business related purposes;
- The warranty card that is not filled out or does not bear the seller’s seal;
- The warranty card that does not bear the bearer’s signature;
-  The warranty will become null and void in case of violation of the rules for the operation, transportation 

and storage of the device;

-  Improper or careless installation, improper connection to the mains.

Equipment  maintenance  must  only  be  carried  out  by  qualified 

personnel. During maintenance work, be sure to disconnect the 

mains and generator set to prevent inadvertent switching on of 

the ATS unit.

PLEASE NOTE!

Summary of Contents for KS ATS 4/32 -12

Page 1: ...www ks power de en Please read this manual carefully before use Owner s Manual Automatic Transfer Switch ATS Unit KS ATS 4 32 12 KS ATS 4 32 15...

Page 2: ...found at the end of this manual All information in this manual is correct to the best of our knowledge and belief at the date of its publication The current list of service centers can be found on th...

Page 3: ...k of electric shock _ Avoid direct contact with grounded surfaces pipes radiators etc _ Be careful when working with the power cord Replace it immediately in case of damage as damaged power cord incre...

Page 4: ...Power kW 14 0 21 0 14 0 21 0 Net dimensions L W H mm 220 150 370 220 150 370 Frequency Hz 50 50 Gross weight kg 7 0 7 0 Ambient conditions Operating conditions 10 0 55 0 Storage temperature 100 700 Re...

Page 5: ...f ATS unit is disabled 9 Generator power indicator On generator power is supplied Off no generator power 10 Generator engine operating indicator On engine starts and works properly Flashing start erro...

Page 6: ...enerator engine While the engine receives a start signal the air choke switches to mid position and the time of the electric starter relay is 4 seconds After the generator receives the voltage output...

Page 7: ...seconds After this time power switches will turn on and power consumers will be supplied by the generator The output load indicator 8 will further glow steadily When the mains supply is restored the s...

Page 8: ...ERATOR POWER CONSUMERS Fig 2 ELECTRIC METER ATS CONTROL CABLE 8 pin ATS output on the generator panel The ATS socket is located on the generator panel Connect the ATS unit to the ATS input on the gene...

Page 9: ...www ks power de en 8 ELECTRICAL DIAGRAM 8 Generator Mains Load Generator lamp Mains power lamp JX2 320 contactor Close lamp Alarm buzzer Power switch ATS controller Engine lamp 8 core cable Diagram 2...

Page 10: ...ng of the product as well as instability of the mains parameters The product overload is indicated by melting or discoloration of parts due to the effect of high temperature score marks on the cylinde...

Page 11: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________________...

Page 12: ...www ks power de en 30 Germany ks power de info dimaxgroup de Poland ks power pl info pl dimaxgroup de Ukraine ks power com ua sales ks power com ua CONTACTS...

Reviews: