FUNCTIONS OF GENERATOR
FUNCTIONS OF GENERATOR
1. The generator is started with the dry contact open.
2. Reaction time before starting the generator - 5 seconds
3. The generator stops at the closed dry contact.
4. Reaction time to stop the generator - 30 seconds
5. When the current drops to 20A, the generator will NOT STOP its work, and will continue to work.
6. The generator will stop working when the overvoltage protection is activated when reached 57В.
It is STRICTLY FORBIDDEN TO CONNECT to DRY contact
(CONTROL TERMINAL) WIRES UNDER VOLTAGE. It may
cause the generator to fail.
MANUAL / EXTERNAL CONTROL mode is recommended
for users with good experience with equipment.
IMPORTANT!
IMPORTANT!
STOPPING THE ENGINE
9
TO STOP THE ENGINE, PROCEED AS FOLLOWS:
TO STOP THE ENGINE, PROCEED AS FOLLOWS:
1. To stop the generator in any mode move the switch wheel to the
OFF position.
MAINTENANCE
10
This manual compliance! You can find a list of service center addresses on the website of exclusive importer:
www.konner-sohnen.com
When the “MANUAL / EXTERNAL CONTROL” mode on the front panel is activated, generator control will
occur by means of “dry contact” (Control terminal)
To switch to “MANUAL / EXTERNAL CONTROL” mode you need:
1. Set the mode switch to “MANUAL / EXTERNAL CONTROL”.
2. On the generator panel, turn the switch wheel to the ON position.
3. Connect the wires to the “Control terminal” connectors (not included). To the connectors.
“Control terminal” it is forbidden to connect voltage.
EXTERNAL CONTROL FUNCTIONAL DESCRIPTION
8
konner-sohnen.com
|
6