1. Hardware Description

1.1. Specifications

Classification

Parameter

Specification

Ethernet

No. of Ports

1

Bandwidth

10/100M

Communication Distance

100m

Protocol Mode

Support TCP Server/TCP Client/UDP
Mode

Max. No. of TCP Connections

1

Downstream Serial
Port

Serial Standard

RS485/422

No. of Ports

1

Connector

Terminal block

Cascade Connection/Transparent
Transmission

Bidirectional transparent
transmission

Baud Rate

300~115200bps

Communication Distance

1200m

Power

Power Connector

Dual power inputs

Input Voltage

9~27VDC

Current

80mA @ 12VDC

Physical
Characteristics

Dimensions

75*105*30mm

Installation

Din-rail or wall

Environmental
Limits

Operating Temperature

-40℃ ~ 85℃

Storage Temperature

-60℃ ~ 125℃

Ambient Relative Humidity

5% ~ 95% RH, non-condensing

C2000-B2-SIE0101-BB1 User Manual

5 / 11

SinoCon Co., Ltd. 

www.sinoconsys.com

Summary of Contents for C2000-B2-SIE0101-BB1

Page 1: ...Last updated 2020 11 26 C2000 B2 SIE0101 BB1 User Manual Ethernet 1 RS485 422 Serial to Ethernet Device Serial Device Server SinoCon Co Ltd...

Page 2: ...ware Description 1 1 Specifications 1 2 Apprearance 1 3 Indicators 1 4 Port Description 1 5 Product Dimensions 1 6 Installation Method 2 Package Contents 3 Warranty Policy C2000 B2 SIE0101 BB1 User Ma...

Page 3: ...liability stated by SinoCon in the terms and conditions of sale of its products and SinoCon makes no warranties regarding the sale or use of KonNaD products including the suitability for the specific...

Page 4: ...C2000 B2 SIE0101 BB1 User Manual 4 11 SinoCon Co Ltd www sinoconsys com...

Page 5: ...erminal block Cascade Connection Transparent Transmission Bidirectional transparent transmission Baud Rate 300 115200bps Communication Distance 1200m Power Power Connector Dual power inputs Input Volt...

Page 6: ...1 2 Apprearance C2000 B2 SIE0101 BB1 User Manual 6 11 SinoCon Co Ltd www sinoconsys com...

Page 7: ...tor Steady on Normal power supply Off No power or abnormal power supply please check if the voltage range is 9 27VDC Downstream Serial Port RXD RS485 RS422 data receive indicator Steady on RS485 RS422...

Page 8: ...ess of the converter defaults to 10 1 1 10 the password is invalid and the converter works in TCP client mode and makes a TCP connection to the 8000 port of the server 10 1 1 1 br Turn WP to OFF The s...

Page 9: ...1 5 Product Dimensions unit mm inch 1 6 Installation Method C2000 B2 SIE0101 BB1 User Manual 9 11 SinoCon Co Ltd www sinoconsys com...

Page 10: ...2 Package Contents No Contents 1 Device contain mounting kit 1 2 Terminal block 1 set 3 Installation guide card 1 C2000 B2 SIE0101 BB1 User Manual 10 11 SinoCon Co Ltd www sinoconsys com...

Page 11: ...period or that have been improperly installed incorrectly input voltage improperly used accidental events or natural disasters etc are not covered by the warranty 3 Before accepting the warranty serv...

Reviews: