background image

SPEED DOME CAMERA                                                           

 

 

I N S T A L L A T I O N   P R E P A T A T I O N  

TOOL LIST:

 

Following tools may be needed for the installation:

 

1. 

Screws and nuts

 

2. 

Philips screw driver

 

3. 

Standard screw driver

 

4. 

Wire scissors

 

5. 

Ladder

 

6. 

Drill

 

7. 

Saw.

 

 

 

CABLE:

 

8. 

Video Coaxial Cable

 

9. 

75

 impedance,

 

10. 

Solid copper wire,

 

11. 

95% braided copper shield.

 

 

Check the max transmission distance referring to the chart below.

 

 

Model Distance 
RG 59/U 

750ft(229m) 

RG 6/U 

1,000ft(305m) 

RG 16/U 

1,5000ft(457m) 

 

 

12. 

RS485 Cable

 

13. 

0.56mm (24AWG) twisted pair wire

 

 

 

DIP SWITCH  SETTING

 

 

See appendix I :

 

14. 

Protocol and Baud rate

 

15. 

Dome address

 

16. 

Video cable type

 

17. 

Resistor jumper

 

18. 

Alarm output method

 

 

 

Summary of Contents for SEC-CAM901

Page 1: ...SEC CAM901 SPEED DOME CAMERA...

Page 2: ...SPEED DOME CAMERA Note Read this manual carefully before installation and operation Keep it handy for later reference...

Page 3: ...PARAMETERS 13 Digital Zoom 13 Joystick AF AI 13 AF Resume Time 13 AI Resume Time 13 Iris ALC 13 CAMERA PARAMETERS 14 White Balance 14 BLC Mode 14 PAN TILT PARAMETERS 14 Auto Stop Time 14 Speed Amplify...

Page 4: ...dable FIFO alarm priority levels Alarm driven Pattern preset etc Position Resume After Alarm Variable Cruise Speed 0 1 150 sec OSD Menu for Programmable Functions Proportional Pan Tilt Speed Vertical...

Page 5: ...required Always take safety codes into consideration during installation Use reliable tools only poor quality tools may cause damage to both human and property Check the strength of all item onsite t...

Page 6: ...8 Video Coaxial Cable 9 75 impedance 10 Solid copper wire 11 95 braided copper shield Check the max transmission distance referring to the chart below Model Distance RG 59 U 750ft 229m RG 6 U 1 000ft...

Page 7: ...SPEED DOME CAMERA MOUNT TYPE WALL MOUNT...

Page 8: ...onduct cables through the hole on top of the housing Align the fast connector to bracket and fix with 2 M5 screws NOTE Apply water proof tape to the thread in the case of outdoor dome 5 Connect cables...

Page 9: ...r and Pan Tilt Module Push the black liner into the two tabs Install the pan tilt module with two clips match color of AMP sockets Gently push the module upward until hearing the click NOTE Remove the...

Page 10: ...SPEED DOME CAMERA SYSTEM CONNECTION...

Page 11: ...up success shows up The whole boot up process lasts about 40 seconds This screen display disappears once the dome receives any effective command Protocol Ernitec Baud Rate 4800BPS Camera ID 001 Camera...

Page 12: ...or down to change value move left to save the setting and exit Note To increase the value changing speed hold the joystick up or down for more than 10 seconds For example In order to change BLC LEVEL...

Page 13: ...exit setting Point cursor to Back and turn joystick right to exit Finally turn joystick up or down to select desired ID number When finished move the joystick left to save the settings Name is the tit...

Page 14: ...ly when new password is entered user can get to this menu item If password is not the same as entered the first time it remains unchanged PSWD Protection Switch on and off the password protection to a...

Page 15: ...ils please refer to keyboard or matrix operation manual This item sets the time to restore auto focus after focus is manually changed The default setting is 005 Off Never restore auto focus after swit...

Page 16: ...brightness of the objects in the center of the picture If the backlight is too dark the object on the center of the picture may appear dark So backlight compensation can decrease the brightness of th...

Page 17: ...ck right to desired bit and move the joystick up or down to select desired letter Preset Number 001 Title PRE1 Set Current Test Current Remove Current Back NOTE You can edit 16 bits of letters at most...

Page 18: ...once Use this function to check the tour Run To run the current tour continuously System will loop the tour Back Back to upper menu CRUISE Main Menu Auto Running Cruise Cruise Number 001 Left Position...

Page 19: ...above procedure to complete the title editing Set the position of the first point The following picture shows the setting menu Call Preset 1 To Confirm Speed Set the scanning speed camera movement sp...

Page 20: ...Back This model of speed dome has 7 alarm input channels and 2 output Alarm input signal can come from other devices such as infrared detector and alarm output signal can go to light and DVR etc Alarm...

Page 21: ...arm is activated the doom will run scan 2 When the fourth alarm is activated the doom will run tour 1 ALARM OUT 1 2 Alarm out relays the alarm input signal to other devices e g light and DVR Change th...

Page 22: ...N ON Reset Button This button is for resetting the dome after changing the dipswitch setting The new setting works only after reboot finishes Led Flashing green light means control commands reach the...

Page 23: ...rammable ID Set all 8bits of SW2 to ON to activate soft address Input 10 bit camera SN number and then set dome ID by controller The dome SN number can be found on the side of the camera or on the pac...

Page 24: ...ON ON ON ON Soft Add ON ON ON ON ON ON ON ON ID B1 B2 B3 B4 B5 B6 B7 B8 52 ON ON ON 53 ON ON ON ON 54 ON ON ON ON 55 ON ON ON ON ON 56 ON ON ON 57 ON ON ON ON 58 ON ON ON ON 59 ON ON ON ON ON 60 ON ON...

Page 25: ...ON 152 ON ON ON 153 ON ON ON ON 154 ON ON ON ON Soft Add ON ON ON ON ON ON ON ON ID B1 B2 B3 B4 B5 B6 B7 B8 155 ON ON ON ON ON 156 ON ON ON ON 157 ON ON ON ON ON 158 ON ON ON ON ON 159 ON ON ON ON ON...

Page 26: ...ON ON 246 ON ON ON ON ON ON 247 ON ON ON ON ON ON ON 248 ON ON ON ON ON 249 ON ON ON ON ON ON 250 ON ON ON ON ON ON 251 ON ON ON ON ON ON ON 252 ON ON ON ON ON ON 253 ON ON ON ON ON ON ON 254 ON ON ON...

Page 27: ...diameter of 0 8000mm 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 3...

Page 28: ...g picture for simple connection D should not exceed 7m 2 3 1 2 ON O FF 4 Best Practice In some circumstances user adopts a star configuration in practical connection The termination resistors must be...

Page 29: ...correctly connected Output Voltage of transformer is too low The power board is not working Check the power connection and outlet make sure they are working properly Check power supply and transforme...

Page 30: ...single point ground to the tube Trolley wire is forbidden in such circumstances In strong thunderstorm or high faradic zone such as high voltage transformer substation extra strong lightning proof equ...

Page 31: ...ether based on breach of contract negligence infringement of any rights of any party or product liability relating to the products shall not exceed the price paid by the distributor to the factory In...