Protects your data by supplying battery backup when power fails.
Microprocessor Control
By means of innovative software control programs, the complicated hardware circuitry is inlaid in the powerful
microprocessor. Apart from reduced size, it also lowers the defective rate of UPS.
LCD Display and Audible Alarms
Actively let you know if the unit is on battery mode, if the battery is low, or if there is an overload status.
High quality battery
The selection of high quality sealed lead-acid maintenance free battery maximizes the life span of the battery for enhanced
economic benefits.
Automatic Detection
When the UPS is powered on, it immediately performs an inspection of the battery capacity.
Automatic Voltage Regulation
Corrects over-voltage and under-voltage, without draining the battery. This preserves battery resources and ensures that
your UPS will provide the optimum runtime during a complete blackout.
Surge Protection
Shields hardware from damage
Automatic Charge
The UPS charges its battery whenever it is connected to utility power.
* Waveform is sine wave, with no distortion.
Installation
Inspection
Inspect the UPS upon receipt. The packaging is recyclable. Save it for reuse or dispose of it properly.
Placement
Install the UPS in a protected area with adequate airflow, and away from direct sunlight and excessive dust. Do not operate
the UPS where the temperature and humidity is outside the specified limits in the
Specifications Table.
Connect to Utility
Connect the AC input power connector to utility power to power up the UPS.
Charge the battery
The battery in the UPS will lose some charge in shipping and storage. It will recharge completely after approximately 8 hours
of normal operation. Do not expect full battery runtime during this initial recharge period.
Connect the loads
Plug the loads into the output connectors on the rear of the UPS.
Caution:
Never connect a laser printer or plotter to the UPS with other computer equipment. A laser printer or plotter
periodically draws significantly more power than when idle, and may overload the UPS.
Operation
Switch On
With the UPS plugged in, press and hold the POWER button more than 4 seconds until hear one beep sound to switch the
UPS on. The UPS will perform self-testing each time when it is switched on.
Switch Off
By pressing and hold the POWER button more than 4 seconds until hearing one beep sound.
Self-Test
In normal utility power, push the POWER button less than 1 second and UPS performs a self-test on the battery capacity.
During the self-test, the UPS operates a backup mode, the BATTERY and FAULT icon stay on.
Backup (slow alarm)
When in Backup mode, the BATTERY and FAULT icon illuminates and the UPS emit beep every four seconds. The alarms
stops when the UPS return to the utility power operation. Press the POWER button to stop the beep.
Low Battery (rapid alarm)
In Backup mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shuts down from battery exhaustion
or return to utility power operation.