Protects your data by supplying battery backup when power fails. 

Microprocessor Control 

By means of innovative software control programs, the complicated hardware circuitry is inlaid in the powerful 
microprocessor. Apart from reduced size, it also lowers the defective rate of UPS. 

LCD Display and Audible Alarms 

Actively let you know if the unit is on battery mode, if the battery is low, or if there is an overload status.   

High quality battery 

The selection of high quality sealed lead-acid maintenance free battery maximizes the life span of the battery for enhanced 
economic benefits.

 

Automatic Detection 

When the UPS is powered on, it immediately performs an inspection of the battery capacity. 

Automatic Voltage Regulation 

Corrects over-voltage and under-voltage, without draining the battery. This preserves battery resources and ensures that 
your UPS will provide the optimum runtime during a complete blackout. 

Surge Protection 

Shields hardware from damage 

Automatic Charge 

The UPS charges its battery whenever it is connected to utility power. 
* Waveform is sine wave, with no distortion.

 

 

Installation 

 

Inspection 

Inspect the UPS upon receipt. The packaging is recyclable. Save it for reuse or dispose of it properly. 

Placement 

Install the UPS in a protected area with adequate airflow, and away from direct sunlight and excessive dust. Do not operate 
the UPS where the temperature and humidity is outside the specified limits in the 

Specifications Table. 

Connect to Utility 

Connect the AC input power connector to utility power to power up the UPS. 

Charge the battery 

The battery in the UPS will lose some charge in shipping and storage. It will recharge completely after approximately 8 hours 
of normal operation. Do not expect full battery runtime during this initial recharge period. 

Connect the loads 

Plug the loads into the output connectors on the rear of the UPS. 

Caution: 

Never  connect  a  laser  printer  or  plotter  to  the  UPS  with  other  computer  equipment.  A  laser  printer  or  plotter 

periodically draws significantly more power than when idle, and may overload the UPS.

 

 

Operation 

 

Switch On 

With the UPS plugged in, press and hold the POWER button more than 4 seconds until hear one beep sound to switch the 
UPS on. The UPS will perform self-testing each time when it is switched on. 

Switch Off 

By pressing and hold the POWER button more than 4 seconds until hearing one beep sound. 

Self-Test 

In normal utility power, push the POWER button less than 1 second and UPS performs a self-test on the battery capacity. 
During the self-test, the UPS operates a backup mode, the BATTERY and FAULT icon stay on. 

Backup (slow alarm) 

When in Backup mode, the BATTERY and FAULT icon illuminates and the UPS emit beep every four seconds. The alarms 
stops when the UPS return to the utility power operation. Press the POWER button to stop the beep. 

Low Battery (rapid alarm) 

In Backup mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shuts down from battery exhaustion 
or return to utility power operation. 

Overload (continuous alarm) 

Summary of Contents for CMP Series

Page 1: ......

Page 2: ...y test mode The buzzer emits alarm every four seconds 6 POWER SWITCH Power on off Battery test and buzzer on off 7 OUTPUT SOCKET Connect with load equipment 8 OUTPUT PHONE JACK Connect to the Tel Fax Modem by another phone line 9 INPUT PHONE JACK Insert the phone line into the jack 10 INPUT POWER CORD Connect to the AC Power 11 FUSE SET Built in fuse avoid damaged by short circuit or overload 12 R...

Page 3: ...Back Elevation Digital Display ...

Page 4: ...ould be replaced Specifications Type CMP UPS500 CMP UPS650 CMP UPS800 CMP UPS1000 CMP UPS1200 Capacity 500VA 300W 650VA 390W 800VA 480W 1000VA 600W 1200VA 720W Voltage 165VAC 275VAC Input Frequency 50Hz Voltage 220V 10 Output Frequency 50Hz 0 5 Type Sealed maintenance free lead acid Capacity 1X12V 7Ah 1X12V 9Ah 2X12V 7Ah Backup Time half load Over 8 Minutes Battery Typical Recharge Time 8 hour LCD...

Page 5: ...ed limits in the Specifications Table Connect to Utility Connect the AC input power connector to utility power to power up the UPS Charge the battery The battery in the UPS will lose some charge in shipping and storage It will recharge completely after approximately 8 hours of normal operation Do not expect full battery runtime during this initial recharge period Connect the loads Plug the loads i...

Page 6: ...onnel knowledgeable of batteries and their precautions Keep unauthorized persons away 2 Charge the UPS s battery every 3 months during extended storage 3 Disconnect the power during extended storage to avoid overcharge of the battery 4 Avoid overload or short circuit though the UPS have built in overload and short circuit protecting function Accessories inside packing CMP UPS500 3A 250V fuse IPC T...

Page 7: ...USV Bedienungsanleitung DIGITALANZEIGE LANGES BACK UP AVR SOFTWARE TEL MODEM ANSCHLUSS ÜBERSPANNUNGSSCHUTZ ...

Page 8: ...ie Testmodus Alle 4 Sekunden ertönt ein Alarmsignal Buzzer 6 POWERSCHALTER Spannung ein aus Akkutest und Buzzer ein aus 7 AUSGANGSBUCHSE Verbraucheranschluss USV Ausgang 8 AUSGANG TELEFONBUCHSE Mit anderem Telefonkabel an Tel Fax Modem anschließen 9 EINGANG TELEFONBUCHSE Das Telefonkabel in die Buchse stecken 10 EINGANG NETZKABEL Mit einer Steckdose verbinden 11 SICHERUNG Eingebaute Sicherung um S...

Page 9: ...Ansicht Rückseite DIGITALANZEIGE ...

Page 10: ...enn die USV nach wiederholtem Test zu zeitig vor schwacher Batterie warnt sollte der Akku gewechselt werden SPEZIFIKATIONEN Typ CMP UPS500 CMP UPS650 CMP UPS800 CMP UPS1000 CMP UPS1200 Kapazität 500VA 300W 650VA 390W 800VA 480W 1000VA 600W 1200VA 720W Spannung 165VAC 275VAC Eingang Frequenz 50Hz Spannung 220V 10 Ausgang Frequenz 50Hz 0 5 Typ wartungsfreier Bleigel Akku Kapazität 1X12V 7Ah 1X12V 9A...

Page 11: ...USV nicht bei einer Temperatur und Luftfeuchtigkeit die außerhalb der spezifizierten Grenzen liegt Siehe Tabelle Anschluss an das Stromnetz Um die USV in Betrieb zu nehmen verbinden Sie das Netzkabel mit dem Stromnetz Laden des Akkus Der Akku der USV verliert während der Lieferung und Lagerung einen Teil der Ladung Sie wird innerhalb von 8 Stunden vollständig während des Normalbetriebs aufgeladen ...

Page 12: ...hängig von der Anzahl der Entladungen und der Temperatur Der Wechsel des Akkus sollte nur von einem Techniker vorgenommen werden Halten Sie unautorisierte Personen fern 2 Laden Sie den USV Akku alle 3 Monate bei längerer Lagerung auf 3 Trennen Sie das Gerät bei längeren Lagerzeiten vom Strom um eine Überladung der Batterie zu vermeiden 4 Vermeiden Sie Überladung und Kurzschlüsse auch wenn die USV ...