background image

21472 Speaker stand XL

 

INTENDED USE:    
- Large, up to 2.5 m high stand with a manually adjustable extension for  

-

 speakers with 35 mm inner flange bushing 

FEATURES & CAPABILITIES 
- Permanent high stability and steadiness thanks to the generously   

-

 dimensioned aluminium tubes (ø 35/42 mm) 

- Equipped with integrated shock absorber, speaker fitting aid, patented   

-

 push-button system for height adjustment etc. 

- Suitable for rehearsal rooms, studios, stages and on tour,  

-

 space-saving folding and low net weight 

- Maximum design load: 50 kg* 
- Height 1580 - 2474 mm, base circle ø 1558 mm, weight 4.1 kg

 

SAFETY INSTRUCTIONS (summary)

Please see the attached sheet for precise details. 

 

A. GENERAL

 

- The maximum centric load capacity adds up to 50 kg* 
- Ensure that the floor is suitable, i.e. level and loadbearing 
- Works should be carried out by competent staff (technical and physical) 

 

B. NOTE concerning "PREDICTABLE MISUSE"

 

- Base and extension tube combination must always be installed vertically 
- Do not load the stand only on one side 
- It is not allowed to shift the stand, especially under load  
- For indoor use only 

 

C. BEFORE USE

 

- Undergo a visual inspection - do not use damaged stands 

 

D. ASSEMBLING THE STAND

 

- For maximum stability, set the largest possible root diameter 
- Tighten the clamping screws firmly, but without using any tools. Manual force is quite sufficient 
- The locking pin 

10

 must remain engaged - except when adjusting the height 

 

E. DURING USE

 - Safety during operation is based on: 

1. OBSERVANCE of this instruction manual, especially the points mentioned under A-F 
2. CORRECT OPERATION 

2.

 a. Always carry out works on the stand with two suitable persons  

2.

 b. Never unscrew the locking bolt 

8

 or clamping screw 

7

 of the extension tube in an  

2. b.

 uncontrolled manner 

3. CONTROL of LATERAL FORCES (relevant due to danger of tipping) 

3.

 Lateral forces must be avoided. These occur when: 

3.

 a. the stand is inclined       

3.

 b. the load balance is exocentric     

3.

 c. external shocks such as kicks, pulling on the stand, vibrations, wind, etc. are suffered) 

 

F. AFTER USE

 

- Allow the load to draw in slowly and in a controlled manner with the aid of two suitable persons.

INSTALLATION - / USER INSTRUCTIONS

COMPONENTS

 

After unpacking, visually inspect whether all parts are present and - if identifiable - whether they 
are in order:   

a

 Stand, folded,   

b

 Clamping screw (M8 x 23 mm) for triangular clamp 

c

 Clamping handle (M8 internal thread) of the telescopic bolt clamp 

d

 Instruction manual 

 

ASSEMBLY, DIMENSIONS

 

The 21472 stand is completely pre-assembled ex factory. For installation proceed as follows: 

 

1

 Loosen slightly the clamping screw 

b

 of the triangular clamp.  

2

 Preferably, pull the legs apart simultaneously until... 

3

 ...the connecting struts are horizontal (= maximum root diameter) 

4

 Tighten clamping screw 

b

 again – manual force is sufficient.  

4

 NOTE: Avoid overtightening - it strains the components.

TECHNICAL DATA

Thank you for choosing this product. Please read and follow carefully the instructions. They 
inform you about all important steps, that are required for a safe assembly and operation. 
Please keep the instructions for future reference.

KÖNIG & MEYER

 GmbH & Co. KG  

Kiesweg 2, 97877 Wertheim, www.k-m.de 
21472-000-55  Rev.01. 4/20

Material

Base and stand tubes: aluminium, black 
Extension tube: steel, powdered, black 
Struts, screws, rivets: steel 
Clamps, handles, attachment aid: PA 
Parquet protectors, dampener: TPE 

Dimen-
sions

Max. base circle: ø 1558 mm    
Height: min.1580 - max. 2474 mm 
Packing size: 1302 x 138 x 120 mm 
Net weight: 4.1 kg 

Load

max. 50 kg*

Pull-out

ø 35 x 894 mm / mounting aid

Box

1300 x 140 x 140 mm

Accessories 
(optional)

Carrying case 21319 
(for one 21471) 
Flange adapter (19654, 19656)  
Mounting adapter (19580, 24281) 
Warning strip 21402 
Leveling leg 21445

* With centric loading, on a horizontal surface and without lateral forces  
* (wind, shocks etc.)

ASSEMBLY, DIMENSIONS

Top view

Depth of 
the K&M 
flange 
adapter 
19656

Root circle diameter 1238

T

ipping line

Centre

COMPONENTS

Summary of Contents for Speaker stand XL 21472

Page 1: ...d unbedingt zu vermeiden Sie treten auf bei 3 a schr g stehendem Stativ 3 b au ermittigem Schwerpunkt der Traglast 3 c externen Schocks St e Zerren am Stativ Ersch tterungen Wind etc F NACH DER BENUTZ...

Page 2: ...e ERSTE PERSON bei schweren Lasten ggf mehrere Personen ERSTE PERSON bedient das Auszugrohr mit der Traglast 6 11 ZWEITE PERSON bedient an der Spannschelle ZWEITE PERSON a die Klemmschraube 7 13 und Z...

Page 3: ...Sie die Angaben im Kapitel AUFSTELLANLEITUNG F r maximale Standfestigkeit stellen Sie den gr tm glichen Fu kreisdurchmesser ein Dieser Zustand ist gegeben bei waagerechter Position der Fu streben WAR...

Page 4: ...zw erst nach einer qualifizierten Reparatur Der Austausch loser Bauteile z B Parkettschoner Klemmschrauben kann vor Ort erfolgen Reparaturen bzw der Ersatz unl sbar verbundener Teile Rohre Schellen Ni...

Page 5: ...a the stand is inclined 3 b the load balance is exocentric 3 c external shocks such as kicks pulling on the stand vibrations wind etc are suffered F AFTER USE Allow the load to draw in slowly and in...

Page 6: ...FIRST PERSON operates the extension tube with the load 6 11 SECOND PERSON attends to the clamp SECOND PERSON a the clamping screw 7 13 and SECOND PERSON b the locking pin 8 10 12 ATTENTION If FIRST PE...

Page 7: ...mentioned in the chapter INSTALLATION INSTRUCTIONS For maximum stability set the largest possible root diameter This condition is given when the position of the bracing is horizontal WARNING A bracing...

Page 8: ...screws can be replaced on site Repairs or the replacement of inseparably connected parts tubes clamps rivets struts must be carried out by qualified local personnel or at the manufacturer s premises...

Reviews: