TECHNICAL DATA
KÖNIG & MEYER
GmbH & Co. KG
Kiesweg 2, 97877 Wertheim, www.k-m.de
24624-000-55/76 Rev.09/Rev.01 03-80-834-00 12/18
Material
Plate, Feet, Tubes: Steel, black powder coated
Threads: Steel, galvanized
Brackets: Zinc die-cast, black powder coated
Cable protection: PA-6, black
Handle: TPE, black
Load
max 18 kg centered
Dimensions
W x D x H: 550 x 550 x 2400 mm
Box
Base: 670 x 670 x 35 mm
Tube combination: 1400 x 115 x 5 0mm
Weight
18 kg
Accessories
(optional)
Crossbars 21390, 21393
Carrier bag for base plate 24627
CHECK, MAINTENANCE, CLEANING
- Careful use of the stand maintains the use of the extension tube and the load bearing
-
functionality of the stand as well as the safety of the installation.
- Perform maintenance only without the lighting attached and watch for possible risks
-
(pinched fingers, impact, the stand falls over).
- To care for the product use a damp cloth and
-
a non-abrasive cleaning agent.
MOUNTING LIGHT(S) TO THE STAND
ATTENTION!
Do not underestimate the weight of the lights
12
placement and extension of the lights must be
10
carried out by physically fit technicians.
10
Firmly grasp the tubes and secure with
10
the locking pin.
MOVING THE LIGHT STAND (LOAD)
Technicians:
FP - First Person:
operates the distance rod
with the weight
SP - Second Person:
operates the clamping bracket's
clamping screw and locking pin
Order when extending the stand:
FP
13
holds the extension tube
SP
14
loosens the clamp screw
12
and holds it
15
pulls the locking pin until
13
the locking pin is no longer
13
in the locked position
FP
16
extends the extension tube and
14
lighting to the desired approx. height;
14
NOTE:
14
to find the pin hole easily
14
the locking pin
14
should be placed
14
just above the hole
SP
17
let go of the locking knob,
15
so that the pin can click into
15
the extension tube
FP
18
slowly lowers the extension tube
16
until the locking pin locks
SP
19
tightens the clamping screw
17
(manual strength is enough)
When retracting the weight
the reverse order applies
IMPORTANT: Ensure that one
person immediately tightens the
locking pin
17
if a second person
cannot securely hold the
extension tube.
FAULT-FINDING (F) and REPAIR (R)
F: The base plate rocks back and forth on the floor:
F:
R: Check if the surface is even
F:
R: Base plate feet
9
are loose?, tighten with a socket wrench (SW8 = M5)
F: The tube combination is not sturdy i.e. is leaning to one side:
F:
R: Check to ensure that the M-20 bolt is tight, Securely screw in the
F: R:
tube combination
3
F:
R: Counter nuts
4
are loose? Tighten with Allen wrench (SW40)
F:
R: Check to ensure that the tube combination is straight
F:
R: Ensure that the surface this even
F: The tube combination is facing in the wrong direction:
F:
R: Loosen the counter nut
4
, Place the tube combination in the desired
F: B:
direction
6
and secure the position by tightening the counter nut
7
USAGE NOTES / FUNCTION
Application examples (not included delivery)