SAFETY NOTES

- Maximum centric load 30 kg 
- Before and after use check stand for damage. Damaged Stands may not be used. 
- Weight distribution must not allow the stand to list to one side   
- The floor must be load bearing and even. 
- In unsafe circumstances (surface, wind etc.) we recommend that the stand be rigged;  

-

 to do this use the clamping ring 

9

- Prior to installation check if the stand load and aids (ladders among other aids) are in working order. 
- Ensure use of suitable lighting and speakers; i.e. the connection adapters must be equipped  

-

 with the proper dimensions and quality. 

- Keep unauthorized personnel away from the stand. Protect against risk of tripping or the stand  

-

 falling over. 

- Maintain safety when installing the system:  

-

 - Ensure the screws are properly tightened. 

-

 - the maximum stability is given when the base struts of the stand are level. 

-

 - The crank button must be in the correct position (has clicked into place) unless the crank is  

-

 

-

 being used to extend or retract the tube. 

- ENSURE: moving a stand with the speakers attached can result in damaging the stand's base. 
- Careful and attentive handling is required when adjusting the stand - due to the possibility of  

-

 pinching or wedging your hand. 

TECHNICAL DATA

KÖNIG & MEYER

 GmbH & Co. KG  

Kiesweg 2, 97877 Wertheim, www.k-m.de 
24610-009-55  Rev.22  03-80-638-00  10/19

Material

- Base tube, Leg Tubes , Struts: Aluminum 
- Extension Tube, Bolts, Connectors: Steel 
- Bracket, Housing: zinc-die cast 
- Guides: Polyamide (PA) 
- End caps, Shock absorbers: TPE

Bearing Load

- max. 30 kg centric load

Dimension

- max. surface circle ø 1320 mm 
- Height 1865-3040 mm 
- Extension tube: ø 35 mm M10 socket

Package, kg

W x D x H: 175 x 195 x 1730 mm, 8,0 kg

Accessories

- Rigging 24613

Accessories 
(optional)

- Carrying Case 24611 
- Crossbars 213/9 a. 21393 
- Adapter 19580, 19656, 24281 etc.

CHECK, MAINTENANCE, CLEANING

- Careful use of the stand maintains the use of the 

-

 telescope and the load bearing functionality of the  

-

 stand, as well as the safety of the installation 

- Perform workstation maintenance only without the  

-

 lighting/speakers attached and watch for possible  

-

 risks (pinching, the stand is bumped or falls over) 

- To care for the product use a damp cloth and a non- 

-

 abrasive cleaning agent. 

 

FAULT-FINDING (F) and REPAIR (R)

 

(F)

: Stand is not stable 

(F)

(B)

: Ensure that the surface is even  

(F)

(B)

: Ensure that the base is expanded to its full  

(F)

(B)

expanded position and tighten the clamp screw

 

(F)

: The extension tube is loose i.e. retracts when the  

(F)

speakers are attached 

(F)

(B)

: Check if the button on the crank is in the  

(F)

(B)

correct position (has clicked into place) and  

(F)

(B)

tighten the clamp screw

ENSURE 
The crank system is used for easy extension and retraction of the speakers 
(load). However, do not underestimate the weight of the lighting/speakers 
(max. 30 kg), which must be placed on the stand tube,  
i.e.: knowledgeable and physically fit individuals are needed,  
depending on the load weight – this can require 2 - 3 individuals. 

C. MOVEMENT 

C.

 OF THE LOAD 

 
In contrast to other stands 
one individual is able to 
move the speakers to the 
desired height by simply 
using the crank system. 
 
SEQUENCE WHEN 
EXTENDING AND 
RETRACTING 
THE SPEAKERS

USER INFORMATION / FUNCTIONS 
B. PLACEMENT and EXTENSION 

B.

 of the LOAD (Crossbars, Speakers) 

1

  

Loosen the   
clamp screw

2

  

Turn the crank and keep 
the button pushed while  
turning the crank handle

3

 

As soon as the desired  
height has been 
reached release the 
button and  in some 
cases a half of a turn 
of the crank is still 
required

4

  

Tighten  
the clamp screw

Application Examples (not included in the delivery)

K&M-Crossbars

K&M-Flange Adapters

Summary of Contents for 246/1

Page 1: ...rfestes Anziehen belastet die Bauteile und ist zu vermeiden A 15 Inbusschraube in oberer Schelle mittels beigefügtem Inbusschlüssel leicht lösen A 16 Obere Schelle jetzt soweit nach unten schieben bis A 17 Verbindungsstreben waagerecht stehen A 18 Inbusschraube mittels Schlüssel wieder festdrehen A 19 Montage der Abspannscheibe siehe Anleitung 24613 A 10 Funktion der Sechskantschraube siehe Kap B ...

Page 2: ...mm mit Buchse M10 Packmaß kg B x T x H 175 x 195 x 1730 mm 8 0 kg Zubehör inkl Abspannvorrichtung 24613 Zubehör optional Tragetasche 24611 Traversen 213 9 u 21393 Adapter 19580 19656 24281 etc PRÜFEN INSTANDHALTEN REINIGEN Schonender Umgang mit dem Stativ erhält die Teleskopierbarkeit die Tragkraft und die Sicherheit der Installation Bei Wartungsarbeiten stets im unbelasteten Zustand auf evtl Gefä...

Page 3: ...t do not over tighten this will negatively affect the A 14 components and should be avoided A 15 Loosen the hexagon socket screw in the upper bracket using the hexagon key A 16 Push the upper bracket downwards until A 17 the connecting struts are level A 18 Use the hexagon key to re tighten the hexagon socket screw A 19 Assemble the rigging ring refer to Instructions 24613 A 10 Function of the hex...

Page 4: ...ing 24613 Accessories optional Carrying Case 24611 Crossbars 213 9 a 21393 Adapter 19580 19656 24281 etc CHECK MAINTENANCE CLEANING Careful use of the stand maintains the use of the telescope and the load bearing functionality of the stand as well as the safety of the installation Perform workstation maintenance only without the lighting speakers attached and watch for possible risks pinching the ...

Reviews: