4
CALIBRATION
To ensure an accurate measurement, it is recommended to check the weight of an empty cup every time you
turn on the unit. It should read 0 gram (or oz) for your empty cup.
Calibration for the cup is needed
ONLY
if the reading of your
EMPTY
cup is higher than zero (gram, oz, cups,
fl oz or ml). The calibration process will reset the reading to zero for the empty cup.
To calibrate,
1) Make sure the transparent cup is attached to the base
2) Make sure the cup is empty. Clean the unit with a dry cloth to remove any excess liquid in the cup
3) Turn on the unit by a pressing the [0] button once
4) Make sure the cup is placed steadily on a flat surface. Press and hold the [0] button for 6 seconds until
“CAL” flashes. Do not touch or move the cup when “CAL” is flashing
The display reading will show “0” and the calibration is completed.
CLEANING AND STORAGE
-
The transparent cup is detachable for cleaning. Press the button below the handle to unlock and detach
the cup from the base
-
Only clean the transparent cup with cold or warm water together with an optional mild cleaning detergent.
Do not use hot water to clean the transparent cup as it can withstand max. 70 ºC
-
Detach the transparent cup and use a damp cloth to clean the base and the handle
-
Never immerse the base and handle in water or place in dishwasher for cleaning
Storage
-
To extend the product life span, remove any food or liquid from the cup scale when it is not in use so that it
is not loaded with weight
-
After cleaning, place the cup scale in a location with good air ventilation
LOW BATTERY INDICATION
The scale indicates it’s low battery status. Replace the batteries and follow the procedure in this instruction
manual to replace the batteries.
SPECIFICATIONS
• Maximum temperature:
The transparent cup can withstand up to maximum 70 ºC
• Maximum display range: 3000 gr, 1420 ml, 6 cups, 48 fl oz
• Volume resolution:
1/8 cup, 1/8 fl oz, 1 ml
• Weight resolution:
1 gram, 1/8 oz
• Battery:
1x CR2450 (incl.)
Safety precautions:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
To reduce risk of electric shock, this product should ONLY be opened by an
authorized technician when service is required. Disconnect the product from
mains and other equipment if a problem should occur. Do not expose the
product to water or moisture.
Maintenance:
Clean only with a dry cloth. Do not use cleaning solvents or abrasives.
Warranty:
No guarantee or liability can be accepted for any changes and modifications of the product or damage caused
due to incorrect use of this product.
General:
Designs and specifications are subject to change without notice.
All logos brands and product names are trademarks or registered trademarks of their respective holders and
are hereby recognized as such.
Keep this manual for future reference.