ATTENTION!!

Read this manual carefully before installing the IP Reader!

Mains connection

Guarentee

Security

Before connecting the appliance to the mains, check that the mains supply voltage corresponds
to the voltage printed on the type plate of the adapter. If the mains voltage is different, consult
your supplier.

No guarantee can be given if safety regulations are not followed.

Always disconnect the power supply before handling anything inside the device.

This device is in conformity with the EMC directive and low-voltage directive.

CE Conformité Europeène (Conform European Norm)

End of life directives

Inepro is paying a lot of attention to environmentally-friendly production. Your new device contain
materials which can be recycled and reused. At the end of its life specialised companies can
dismantle the discarded device to recycle the reusable materials and to minimise the amount of
materials to be disposed of. Please observe the local regulations regarding the disposal of
packaging materials, exhausted batteries and old equipment.

This device may only be used indoors.

Indoor User Only

Directives

Version 2.0.1    -    I

Summary of Contents for inpro

Page 1: ...2014 Inepro B V All rights reserved Technical Manual Inepro IP Reader Konica Minolta Inepro IP Reader Konica Minolta Product Version Rev 3 Version of this manual 2 0 1...

Page 2: ...This manual contains information on how to do that please read it carefully Due to continuous product improvements this manual is subject to changes without notice We strongly recommend you read the l...

Page 3: ...eparation of this document the publisher and the author assume no responsibility for errors or omissions or for damages resulting from the use of information contained in this document or from the use...

Page 4: ...troduction 2 Components 5 Operating Procedures 8 Communication 10 Network Connections 13 LEDs Light Emitting Diodes 16 Software configuration settings 21 Inepro Business Server Optional 29 Specificati...

Page 5: ...device is in conformity with the EMC directive and low voltage directive CE Conformit Europe ne Conform European Norm End of life directives Inepro is paying a lot of attention to environmentally fri...

Page 6: ...I Introduction Part...

Page 7: ...fare Desfire KoMi 361102 Inepro IP Card Reader Legic Prime KoMi 361103 Inepro IP Card Reader Legic Advant KoMi 361104 Inepro IP Card Reader HiD iClass KoMi 361105 Inepro IP Card Reader HiD Prox KoMi 3...

Page 8: ...Konica Minolta Topics The following topics will be addressed 1 The components in the IP reader set 2 The operating procedures 3 Network Connections 4 Software configuration settings 5 Connecting to t...

Page 9: ...II Components Part...

Page 10: ...der consists of the following components Grey Card Reader Housing Grey Antenna Box Antenna Box Cap 1 Grey Antenna Box Cap 2 Grey Controller Box Wire Duct Grey Network Cables Network Cable UTP C5E Patc...

Page 11: ...uide Inepro Manuals Cable clip Cable clip PK 250 Self Adhesive Fastener 6 x 6 mm Check Components Please check if all the components are in the set before you continue with the installation and setup...

Page 12: ...III Operating Procedures Part...

Page 13: ...d communicates with the card reader When a card is presented to the reader it will read the card s data The IP controller board makes a request to the card reader for the data The IP controller board...

Page 14: ...IV Communication Part...

Page 15: ...he security of the card data an AES Advanced Encryption Standard encryption is applied to the data Encryption The encryption key is renewed with every connection so it is not possible for another devi...

Page 16: ...11 Inepro IP Reader Konica Minolta IP Reader encryption protocol...

Page 17: ...V Network Connections Part...

Page 18: ...can be used normally to connect to the wall outlet and the Ethernet device But the IP controller board can also be supplied with energy by a Power over Ethernet switch In this case the connection fro...

Page 19: ...ions IP Controller Board IP Controller Board LED s RS232 Led on Communication between card reader and controller board is OK RUN led on Program in the micro on the IP controller board runs correctly C...

Page 20: ...VI LEDs Light Emitting Diodes Part...

Page 21: ...e user know that card data has been read and this data is presented to the server The LED will also be used to show an error has occurred by using different blink patterns Blink patterns In case of an...

Page 22: ...ort pulse 0 5 seconds Wiegand Card presented correctly server received the data OK Long pulse 2 4 seconds Error Codes Also the server can generate error codes These error codes are shown when the card...

Page 23: ...ly accessed 1 The card data was presented to the server 2 seconds ago ETH Green Running OK On ETH Orange Running OK Blinking Footnotes 1 There are card readers that have a protocol installed where the...

Page 24: ...ng as a network switch router LED Status Display Green or orange PoE Connection exists On Connection does not exist Off Orange or green PoE Data is being transmitted Blinking at transmission speed Bad...

Page 25: ...VII Software configuration settings Part...

Page 26: ...nfiguration settings can be managed using the IP card reader config tool When you start the configuration set up program this screen will be displayed Press the button to search for connected IP Reade...

Page 27: ...er is up and running the next screen will be displayed The DHCP server has found the IP Reader and has displayed the host name PoE Test The IP address is also retrieved and displayed Select an IP Read...

Page 28: ...scription Dynamic Host Configuration Protocol Enabled if DHCP be used disabled if the network information need to be filled out manually IP The IP address for the IP reader Netmask The netmask only us...

Page 29: ...he name of the server can be entered the IP address value for this server will be ignored and retrieved from the DNS server Key set Key set will give the possibility to set the encryption key between...

Page 30: ...eader software will enable you to select one of the protocols Remark all types in setting 0 means All types except 2 and 128 255 0 All types except value 2 and 128 255 1 H10301 26 8 bit 2 H10302 37 no...

Page 31: ...50 hitag1 hitag2 and Ti RFID The card data of the EM4x02 and EM4x05 cards will be processed and send in reversed order Setting 2 Not applicable Setting 3 Not applicable Data 1 Not applicable Data 2 No...

Page 32: ...re are not influenced by these settings 0 Card serial number is calculated from the raw data in the reversed order 1 Card serial number is calculated from the raw data in the normal order Setting 2 Le...

Page 33: ...VIII Inepro Business Server Optional Part...

Page 34: ...system uses an Inepro Business Server you should follow these instructions to register your IP reader with it otherwise skip this chapter you have finished installing your IP reader Warning The Inepr...

Page 35: ...o Business Server Config settings manager this will be installed in the Back Office Suite directory by default in the C Program Files Inepro directory 2 Right click on System default and choose Insert...

Page 36: ...Terminal menu 6 Click on the group and right click Group Settings A menu will be shown choose Insert The pop up window below appears 7 Choose the setting IPReaderID 8 Retrieve the IP Reader serial MA...

Page 37: ...nager in the Advanced Terminals menu 13 These terminals can now be connected to a Multifunctional like you would connect a PayCon terminal 14 Refer to the Inepro Back Office Manager manual for more de...

Page 38: ...IX Specifications Part...

Page 39: ...eader 3 VA Housing Material PC ABS crash flame and scratch resistant plastic Colour Antenna Board Housing Grey Colour Controller Board Housing Light Grey Dimensions Controller Board Housing 11 5 x 16...

Page 40: ...35 Inepro IP Reader Konica Minolta This page is blank intentionally...

Page 41: ...X Appendix I Part...

Page 42: ...37 Inepro IP Reader Konica Minolta...

Page 43: ......