![Konica Minolta EK-604 Installation Manual Download Page 3](http://html1.mh-extra.com/html/konica-minolta/ek-604/ek-604_installation-manual_1994550003.webp)
E-3
10. Connect the connector removed in step 7 to the
interface board unit.
11. Remove the connector from the wire saddle
located on the main body.
12. Connect the connector removed in step 11 to the
local interface board unit.
13. Insert the two cables connected to the local
interface board unit into the wire saddle.
14. Connect the USB unit to the local interface
board unit with the supplied USB cable. Insert
the USB cable into the wire saddle.
Note:
Route the USB cable so that it presses down the
two cables that are connected to the local inter-
face board unit.
A0YCIXC011DB
A0YCIXC012DB
A0YCIXC013DB
A0YCIXC014DB
Wire saddle
A0YCIXC015DB
Wire saddle