Chapter 3 Troubleshooting
3-19
3.2.8 06350 ~ 06385: Receiver Sensor Errors
•
Error codes S column: Errors at the read operation/calibration.
•
Error codes E column: Errors during erase operation.
•
Error codes I column: Errors during initialization.
References for response method
•
See
"2.5.2 Receiver unit (Page 2-12)"
for the position of the receiver, the justifier guide, and the
receiver sensor.
•
See
for the position of the MDU.
•
See
"5.4.10 Replacing the Receiver (Receiver Unit Assembly) (Page 5-55)"
for the method to
replace the receiver.
•
See
"5.4.11 Replacing the Justifier Guide Unit Assembly (Page 5-57)"
for the method to replace the
justifier guide.
•
See
"5.4.5 Replacing the Receiver Sensor (Page 5-46)"
for the procedure to replace the receiver
sensor.
•
See
"5.10.2 Replacing the MDU (Page 5-116)"
for the procedure to replace the MDU.
Error code
Description of the error
Response
(References to replacement methods are
listed at the end of the table.)
S
E
I
06350 06365 06380
Receiver sensor error (when
receiving cassette)
Receiver sensor did not go ON
when receiving the cassette.
1. Confirm that there are no scratches or
foreign objects on the cassette, the
receiver, and the justifier guide.
Replace with new parts if there are any
scratches, or remove any foreign
objects.
2. Confirm that the sensor dog on the
receiver sensor is not deformed, and
replace it if there is any deformafion.
3. Confirm following and replace the
faulty parts.
•
Receiver sensor
•
Sensor wire:
JP42 ~ JJ17/JP17 ~ MCN3 (MDU)
•
MDU
06351 06366 06381
Receiver sensor error (when
moving cassette)
Receiver sensor went OFF
when moving the cassette.
06352 06367 06382
Receiver sensor error (when
ejecting cassette)
Receiver sensor went OFF
when ejecting the cassette.
06353 06368 06383
Receiver sensor error (when
removing cassette)
Receiver sensor did not go OFF
after removing the
cassette.(Insertion slot
detection sensor is OFF)
06354
Cassette during the startup
(receiver)
Receiver sensor was ON during
the initialization by PowerON.
1. Confirm for foreign object inside the
equipment, and remove it if there is
any.
2. Confirm following and replace the
faulty parts.
•
Receiver sensor
•
Sensor wire: JP42 ~ JJ17/JP17 ~
MCN3 (MDU)
•
MDU
06355 06370 06385
Cassette during the
initialization (receiver)
Receiver sensor was ON during
the initialization after closing the
second front door.
Summary of Contents for 0902
Page 2: ......
Page 6: ......
Page 12: ......
Page 30: ...2 10...
Page 54: ......
Page 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Page 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Page 120: ......
Page 296: ...8 10...
Page 300: ......
Page 301: ......