2
HAT PROCEDURE EK80
2.1
Hardware and Software registration
In Table 3 List of Items, fill in the information for all the units supplied by Kongsberg Maritime.
The items supplied can be:
•
Computer
•
Network switch
•
WBTs
•
Transducers
2.2
Visual inspection
Perform a visual inspection of all the units in the system. Make sure that they are mounted
properly and do not have any physical damage or scratches.
Also, check that the equipment and the belonging cables are installed according to the
requirements in the installation manual. Check that the units and cables are located so that the
risk of electrical interference is kept at a minimum.
2.3
Test Procedure
To start testing the system, make sure all units are powered on.
2.3.1
Check installation
Open the installation menu in the EK80 software and verify:
•
All WBTs and/or ADCP transceivers are installed, including proper licenses
•
All transducers installed and connected to the correct transceiver (WBT).
2.3.2
Configuration of interfaces
Verify that all ship interfaces are turned on and operational.
In the
Installation -> I/O Setup
configure the required inputs and outputs. Configure both the
serial ports and the LAN ports according to the system interconnection and setup
documentation.
As a minimum the following inputs must be set up:
•
GPS position
•
Heading of the vessel
•
Motion data of the vessel
Note!
If an ADCP is included in the system, the motion data must be in the KM Binary
format.
Note!
If an ADCP is included in the system, it is essential that the ADCP is synchronised to
an available NTP server for accurate timing. The time synchronisation settings can be
checked in the ADCP Editing menu.
Other examples of inputs and outputs may be: