442700/A
645
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 10 VA (Approximately)
The power supply is connected to a dedicated socket on the rear side of the Processor Unit.
Related topics
Power requirements, page 644
Technical specifications, page 639
Operating Panel power requirements (Mk2)
•
Make and model
: CS90 Operating Panel Mk2
•
Voltage requirement
: 115/230 VAC, 47 to 63 Hz, single phase, nominal
•
Maximum voltage deviation
: 15%
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 10 W (Approximately)
Related topics
Power requirements, page 644
Technical specifications, page 639
Operating Panel power requirements (Mk3)
•
Make and model
: CS90 Operating Panel Mk3
•
Voltage requirement
: Not applicable
This unit is powered by means of the USB connection.
Related topics
Power requirements, page 644
Technical specifications, page 639
Transceiver Unit power requirements
•
Make and model
: CS90 Transceiver Unit
•
Voltage requirement
: 230 VAC, 47 to 63 Hz, single phase, nominal
•
Maximum voltage deviation
: 15 %
Summary of Contents for Simrad CS90
Page 1: ...kongsberg com simrad Simrad CS90 REFERENCE MANUAL ...
Page 2: ......
Page 627: ...442700 A 625 Related topics Concept descriptions page 622 Concept descriptions ...
Page 683: ......
Page 684: ... 2021 Kongsberg Maritime ISBN 978 82 8066 213 2 ...
Page 685: ......
Page 686: ...Reference Manual Simrad CS90 ...